Troubleshooting

Little or no cutting 
fluid is being 
pumped. Pump and 
motor may also 
vibrate or be noisy.

1.

No power; voltage is incorrect.

1.

Switch power supply ON/verify machine and pump 
voltages match.

2.

Blown fuse/tripped circuit breaker 
at main panel.

2.

Correct the cause of overload, then reset/replace 
fuse or breaker.

3.

Coolant level is too low, and pump 
cavitation is occurring.

3.

Fill coolant tank with a minimum of four gallons of 
cutting fluid.

4.

Coolant is incorrect, or is too thick 
and incorrectly mixed.

4.

Use water-soluble cutting fluid, or add water to 
lower fluid viscosity.

5.

Pump is operating in reverse.

5.

Pump power supply wires are connected out of 
phase. Swap any two pump power supply power 
leads.

6.

Motor or cover is loose.

6.

Tighten any loose fasteners.

Debris is obstructing pump suction 
or impeller is damaged.

Remove pump, remove impeller cover, clean and 
replace as required.

8.

Plug or receptacle is corroded or 
mis-wired.

8.

Clean/retighten contacts; correct the wiring.

9.

Break or short in wiring; or loose 
connections.

9.

Trace/replace broken or corroded wires; fix loose 
connections.

10.

Pump ON/OFF switch at fault.

10.

Replace switch.

11.

Motor connection wired incorrectly.

11.

Wire motor correctly (refer to inside junction box 
cover or manual).

12.

Emergency stop button is at fault.

12.

Reset or replace emergency stop switch assembly.

13.

Thermal relay has tripped.

13.

Improve pump motor cooling and airflow. 
Disconnect machine from power, manually reset 
thermal relay, and slightly turn-up trip setting.

14.

Transformer is at fault.

14.

Test/replace transformer. 

15.

Contactor not energized/has poor 
contacts.

15.

Test all legs for power, test field coil and replace if 
at fault.

16.

Motor at fault.

16.

Test for shorted windings, bad bearings and repair 
or replace.

7.

7.

Symptom

Possible Cause

Possible Solution

Содержание SB1044

Страница 1: ...lts especially on materials that should not be ground dry Figure 1 Model SB1044 Unpacking This item was carefully packaged to prevent damage during transport If you discover any damage please immediat...

Страница 2: ...ose clamp 9 Route the delivery hose out of the way and fasten the delivery hose to your desired cutting fluid nozzle with the hose clamp 10 Fill the tank with premixed water soluble cutting fluid To i...

Страница 3: ...sure the cutting fluid is properly serviced and the tank is filled 2 Put on the necessary personal protection equipment 3 Position the cutting fluid nozzle for your operation 4 Use the control panel c...

Страница 4: ...is turned ON 5 Open the flow lever on your cutting fluid nozzle all the way open and turn the cutting fluid pump ON Do not leave the area as you will need transfer the hose to the other bucket to prev...

Страница 5: ...is obstructing pump suction or impeller is damaged Remove pump remove impeller cover clean and replace as required 8 Plug or receptacle is corroded or mis wired 8 Clean retighten contacts correct the...

Страница 6: ...serious injury or fire 4 Motor Wiring The motor wiring shown in these diagrams is current at the time of printing but it may not match your machine Always use the wiring diagram inside the motor junc...

Страница 7: ...mp To Motor To Power Cord 0 W1 V1 U1 W1 V1 U1 NO 98 Ground 3 2 1 4 6 5 W1 V1 U1 Gn OPTIONAL 440V 3 PHASE CONNECTION W V U 0 7 6 4 3 2 R1 T1 1 T1 R1 R1 R1 1 1 1 1 2 2 2 3 3 6 7 3 3 0 0 U U V V W W 4 4...

Страница 8: ...chantability or fitness for any purpose are hereby limited to the duration of this warranty To take advantage of this warranty contact us by mail or phone to give us the details of the problem you are...

Отзывы: