-28-
For Machines Mfg. Since 7/09
Model SB1016/SB1036
P R E P A R A T I O N
23.
Lift the chuck guard shown in
Figure 28
,
and try to start the lathe again. The cover
kill switch should prevent the lathe from
starting while the guard is open.
Figure 28. Chuck safety cover.
24.
Close the chuck guard.
25.
Open the cutting fluid valve, and using the
pump switch shown in
Figure 28
, turn the
cutting fluid pump
ON
. Verify that fluid
flows from the nozzle, then turn the cutting
fluid pump OFF.
— If no fluid is pumped, but fluid level is
full, no hose kinks exist, and the cutting
fluid nozzle is open, the pump may be
wired with incorrect phase polarity.
Correct the pump phase polarity wiring as
outlined on
Page 16
.
The test run is now finished. Shut the lathe down
and begin the
Spindle Break-In
procedure.
Cutting Fluid
Pump Switch
Chuck Guard
Spindle Break-In
It is essential to closely follow the proper break-in
procedures to ensure trouble-free performance.
Complete this process once you have familiarized
yourself with all instructions in this manual and
completed the test run.
To complete the spindle break-in:
1.
Make sure you have completed the
Test
Run
procedure beginning on
Page 25
.
2.
Turn the spindle speed dial (
Figure 29
) all
the way counterclockwise to the minimum
speed.
Figure 29. Spindle speed dial.
Spindle Speed Dial
3.
Move the spindle range lever (
Figure 30
) to
low speed range 1 (18-55 RPM).
Note:
You may need to slightly rotate the chuck
by hand to engage the lever.
Figure 30. Spindle range lever in low 1.