![Source 1 S1-THSU302-S Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/source-1/s1-thsu302-s/s1-thsu302-s_owners-manual-and-installation-instructions_1336266043.webp)
39
Advanced Setup Table
Df = Factory Default Setting
Step# Description
Pg# Range
Df
35
3rd StageTurnoff Point
26
Deadband, Setpoint
Deadband
36
4th Stage Turnoff Point
26
Deadband, Setpoint
Deadband
37
Fan Program
27
On, Off
Off
38
Minutes of Fan Runtime
27
0-60
0
39
Fan Program Start Time
27
12:00A - 12:00A
7:00A
40
Fan Program Stop Time
27
12:00A - 12:00A
9:00A
41
Wired Sensor Type
27
Remote, Supply
Remote
42
Control to Temp Source
28
Thermostat, Wired Remote*,
Thermostat
Wireless Remote, Average of
Wireless Remotes, Average
Thermostat and Wired Remote*,
Average All Sensors.
*Option only if prior step =
“Remote”
43
Wireless Remote to Use
28
list of wifi sensors currently
first linked
linked to thermostat.
sensor in
* This step only appears
list
if prior step = “Wireless
Remote”
44
Fan Off Delay
27
0 - 120 Seconds
0
45
F/C
28
Fahrenheit (F), Celsius (C)
F
46
Comfort Recovery
27
On, Off
Off
47
Dry Contact Polarity
29
Open, Closed
Open
48
Dry Contact Use
29
Condensate, Vacation, FDD
Vacation
49
Skyport
29
On, Off
On
50
Local API
29
On, Off
Off
51
ADR
33
On, Off
On
52
ADR Action
33
Observe Setpoint Offset,
Observe set-
Observe Static Setpoints
point offsets
53
Event Max Cool Setpoint
33
65 - 90
90
54
Event Min Heat Setpoint
33
50 - 85
50
55
Static Cool Setpoint
33
65 - 85
82
56
Static Heat Setpoint
33
65 - 85
60
57
Cool Setpoint Offset
34
1 to 10
4
58
Heat Setpoint Offset
34
-1 to -10
-4
59
Press Fan To Clear All Messages
28
Содержание S1-THSU302-S
Страница 6: ...2 Get To Know Your Thermostat Setup Buttons...