Page 8
Wire Connections
If the terminal designations on your old thermostat
do not match those on the new thermostat,
refer
to the chart below or the wiring diagrams
that follow.
* O/B is used if your system is a Heat Pump.
I
Am
Outdoor
COOL SET
HEAT ET
S
2:00
78
74
68
85
MO
YOUR NAME
Wire from the
old thermostat
terminal marked
Function
Install on the
new thermostat
connector marked
G or F
Fan
G
Y1, Y or C
Cooling
Y1
W1, W or H
Heating
W1/O/B
Power
Rh, R, M, Vr, A
R
C
O/B
C
Common
Rev. Valve
W2
2nd Stage Heat
Y2
CKGND
Dry Contact Switch
Y2
W3
W3
H, HUM
HUM
Ck1
Dry Contact Switch
DRY CONTACT
DRY CONTACT
W1/O/B*
W2
D, DEHUM
DEHUM
2nd Stage Cooling
3rd Stage Heat
Humidity
Dehumidity