background image

Safety Instruction 

     

 

 

 

Please conserve this manual as operation guidance. If you sell this product to other user, please 

make sure that they also receive this user manual.   

 

Always make sure that you are connecting to the proper voltage and that the line voltage you are 

connecting to is not higher than that stated on the decal or rear panel of the fixture.   

 

The fixture is intended to indoor use only. To prevent risk of fire or shock, do not expose fixture to 

rain or moisture. Make sure there are no flammable, explosive or corrosive materials surrounded 

in 0.5 meter while operating.   

 

The unit must be installed in a location with adequate ventilation, at least 50CM away from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

 

Do not operate at ambient temperatures higher than 104

(40

).   

 

Safe wire should be used to install machine. Bearing of safe wire should be 3 times of the 

machine weight. Complimentary signal cable transmits signals to 20 unit fixtures at most. Signal 

amplifier is a must to connect more fixtures. Sectional area of complimentary power cable is 1.5

.   

 

Always disconnect from the power source before servicing or replacing fuse/lamp and be sure to 

replace with same fuse/lamp size and type. Cut off power before moving, repairing and cleaning 

the machine. 

 

Secure fixture using a safety chain and carrying handles. Never carry the fixture by its cord. 

 

In case of failure or misfunction occurred, stop using the unit immediately.   

 

Repairs carried out by unskilled people can lead to damage or malfunction. Buy the same spare 

parts/components from manufacturer directly.   

 

To avoid electric shock, all fixtures must be connected to circuits with a suitable ground. Make 

sure the power cord is never crimped or damaged. Do not power on and power off the fixture in a 

short time. For your safety, do not touch fixture when running.   

 

When use DMX controller, please make sure that there is no interference sources(e.g. intercom, 

high frequency radio waves and radiation source) 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or attempt 

any repairs yourself. In the unlikely event your unit may require service, please contact your local 

distribution or after-sale service center. 

CH10 

Stand alone 

speed   

0-255 from slow to fast 

CH11 

Y run speed 

0-255 from fast to slow 

CH12 

LED1 

RGBW  brightness  adjust,2-31RED,32-61  GREEN, 

62-91BLUE,92-121WHITE,122-151 

RED+GREEN,152-181 

RED+BLUE,182-2BLUE,212-G

REEN+BLUE,242-255 RED+GREEN+BLUE+WHITE 

CH13 

LED2 

CH14 

LED3 

CH15 

LED4 

CH16 

LED5 

CH17 

reset 

0-254 not applicable

255 reset 

 

6. Master-Slave control model

 

Set  up  one  fixture  as  Master  fixture(triggering),  other  fixtures  as  slave 
fixtures(receiving  trigger  signals).Set  up  all  fixtures

  same 

address  value  or 

following DMX controller performance(Attention: all fixtures use the same DMX 
channel-12 or 17CH)

 

 

Specification: 

Voltage

AC110V~240V 

Frequency

50/60Hz 

Rated Power: 120W 

LED: 10WX5 RGBW 4IN1 

Control

DMX512 

Channel: 17/12 CH (switchable) 

Control Mode

DMX/sound active/auto/ master-slave/manual 

Level of Protection: IP20 

Stock: Clean and Dry place 

Running Temp.: 0°C~40°C                                                                   

Weight: 6.5KG 

Package Dimension: 58*8*20cm

 

 

 

 

 

 

For your safety

please read this user manual carefully before 

operation. The machine should be operated by qualified engineer

 

 

 

Содержание BEAM-ARC5-10W

Страница 1: ...BEAM ARC5 10W USER MANUAL PRO LIGHTING ...

Страница 2: ...this item and if you want to collaborate we are looking for a feedback from you about the operation of the product and for possible improvements to introduce in the next future Go to our website www soundsationmusic com and send an e mail with your opinion this will help us to build instruments ever closer to customer s real requirements One last thing read this manual before using the instrument ...

Страница 3: ...ace the product in wet or dirty environments Do not remove the protective coverings Do not cover any of the productss ventilation holes Air must circulate freely around the product Do not set the product on a surface with excessive vibration Do not expose the product to high electro magnetic interference Do not expose the product to heat cold wet in improper way in respect to its IP grade Do not l...

Страница 4: ...pact on the environment and human health due to potentially hazardous substances that are generally associated with EEE At the same time your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources For more information about where you can drop off your waste equipment for recycling please contact your local city office waste authority approve...

Страница 5: ...riginal proof of purchase To avoid any damages in transit please use the original packaging if available Alternatively you can send the product to SOUNDSATION SERVICE CENTER Via Enzo Ferrari 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the product For further information please visit www sounds...

Страница 6: ...pare parts components from manufacturer directly To avoid electric shock all fixtures must be connected to circuits with a suitable ground Make sure the power cord is never crimped or damaged Do not power on and power off the fixture in a short time For your safety do not touch fixture when running When use DMX controller please make sure that there is no interference sources e g intercom high fre...

Страница 7: ...f stand alone 120 126 Y off stand alone CH9 Stand alone sound active 127 133 Y sound active 134 140 Y sound active 141 147 Y sound active 148 154 Y sound active 155 161 Y sound active 162 168 Y sound active 169 175 Y sound active 176 182 Y sound active 183 189 Y sound active CH9 Stand alone sound active 190 196 Y off sound active 197 203 Y off sound active 204 210 Y off sound active 211 217 Y off ...

Страница 8: ...and alone 50 56 Y stand alone 57 63 Y stand alone 64 70 Y off stand alone 71 77 Y off stand alone 78 84 Y off stand alone 85 91 Y off stand alone 92 98 Y off stand alone 99 105 Y off stand alone 106 112 Y off stand alone 113 119 Y off stand alone 120 126 Y off stand alone 127 133 Y sound active 134 140 Y sound active 141 147 Y sound active 148 154 Y sound active 155 161 Y sound active 162 168 Y so...

Страница 9: ...TER password default 988 ENTER DMX Protocol 12CH CH Function Description CH1 Y 0 255 CH2 Y 16 bit 0 255 CH3 Dimmer 0 255 from dark to bright CH4 R 0 255 from dark to bright CH5 G 0 255 from dark to bright CH6 B 0 255 from dark to bright CH7 W 0 255 from dark to bright Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end A word on termination...

Страница 10: ...r cables Primary fuse blown Replace fuse Secondary fuse blown Replace fuse Fixture resets but does not respond correctly to controller DMX mode operation Controller not connected Connect controller Incorrect addressing of the fixtures Check address setting on fixture and controller Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking a...

Отзывы: