background image

1.800.338.7337 / www.soundoffsignal.com

1

ENFSLXSS   11.14

INSTALLATION:

SURFACE MOUNT

1) Establish a position on the vehicle. Use the 

gasket (provided) as a template to drill 1/4” 

diameter wire hole and pilot holes for mounting 

screws. Note: pilot holes are 4.91” on center. 

Caution: Do not stretch gasket as this may 

change the required hole spacing.

SAE J595 CLASS 1 SURFACE MOUNTS

ENFSSS(XX)- SINGLE

ENFDSS(X)(XX) - DUAL

TECHNICAL SPECIFICATIONS

SURFACE MOUNT nFORCE

Single Mount

Dimensions:

5.0”L x 1.72”H  x 1.50”D

Double Mount

Dimensions:

5.0”L x 3.13”H x 1.50”D

Input Voltage:

10 - 16 Vdc or 10 - 30 Vdc*

CURRENT CONSUMPTION

10-16 Vdc

10-30 Vdc *

6 LED Single 

12 LED Dual &

18 LED Tri-Color

<1.0A @12.8 Vdc

<0.6A @ 25.6 Vdc

9 LED Single Color

<1.5A @ 12.8 Vdc

<0.9A @ 25.6 Vdc

12 LED Single Color

<2.0A @12.8 Vdc

<1.2A @ 25.6 Vdc

* - Special Order

GASKET

HOUSING

LIGHT ASSEMBLY

SINGLE MOUNT VERSION - DOUBLE MOUNT 

VERSION NOT SHOWN

BACK VIEW OF SINGLE SURFACE MOUNT SHOWN W/O 

RUBBER MOUNTING GASKET

- TYPICAL FOR BOTH VERSIONS-

DO NOT DAMAGE, BLOCK OR 

TOUCH THE BREATHER PATCHES

MAKE SURE DRAIN

HOLE IS FACING DOWN

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at

www.soundoffsignal.com/sales-support

. If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. at 

1.800338.7337

 (press #4 to skip the

automated message). Questions or comments that do not require immediate attention may be emailed to 

[email protected].

SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.

•HIGH CURRENT interconnects must be properly terminated.  Poor crimp quality can cause heat
  build-up and fire.  Follow crimp connector manufacturer instructions.
•DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to vehicle 
  Owner’s Manual for deployment zones.
•Unit may become hot to touch during normal operation.
•Failure to properly install connectors, fuses or wiring may cause vehicle failure or fire.
•Installation must only be performed by trained technician.  Installer must determine vehicle wiring 
  configuration and proper integration of system.
•Use proper wire gauge.  All power wires connecting to positive (+) or negative (-) battery terminal 
  or local chassis ground (-) must be sized to supply at least 125% of max. current and properly fused at 
  power source.
•Install protective grommets when routing wire through firewall or metal. 

WARNING

WIRE HOOK-UP TABLE

WIRE COLOR:

FUNCTION:

 ORANGE OR RED

Power

BLACK

Ground

BLUE OR GREEN**

 Sync2 *

YELLOW OR WHITE 

to GROUND 

Wire Function

-See page 4-

YELLOR OR WHITE 

to POWER

Function Wire

RED/WHITE OR 

ORANGE/WHITE

Power

** To sync multiple nFORCE lights, connect

the Green and/or Blue wires from each light

together.

* Will NOT work w/ other sync products

such as Ghost, LED3, & Intersector.

BLACK

RED

WHITE

GREEN

SINGLE OR DUAL

LIGHT HEAD 1

BLACK

BLUE

ORANGE

YELLOW

DUAL

LIGHT HEAD 2

Sync

Set-up/Function

Sync

Set-up/Function

RED/WHITE

ORANGE/WHITE

+Vdc

A FUSE

5

+Vdc

+Vdc

A FUSE

5

+Vdc

+Vdc

A FUSE

5

+Vdc

A FUSE

5

Содержание nFORCE ENFSSS**-Single Series

Страница 1: ...m to 5 p m at 1 800338 7337 press 4 to skip the automated message Questions or comments that do not require immediate attention may be emailed to techservices soundoffsignal com SUPERIOR CUSTOMER RELATIONSHIPS SMARTLY DESIGNED LIGHTING ELECTRONIC SOLUTIONS HIGH CURRENT interconnects must be properly terminated Poor crimp quality can cause heat build up and fire Follow crimp connector manufacturer ...

Страница 2: ...on and protect the electronics from damage due to heat voltage THERMAL COMPENSATION PROTECTION The LED module is designed to provide maximum power output while providing protection to the electronic components by reducing the output power at extreme temperatures SYNC 2 Syncronizing the flashing of multiple light modules is accomplished by connecting the Green and or Blue wires of different light m...

Страница 3: ...GLE DUAL TRI 12V FLASH FLASH DUAL FLASH CLR 1 2 3 12V FLASH LOW PWR FLASH CLR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V NO OP NO OP NO OP 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLASH CLR 1 2 3 LOW PWR 12V 12V 12V FLASH LOW PWR FLASH COLOR 1 2 LOW PWR FLAS...

Страница 4: ... high then release The flash pattern will advance to the next pattern If the light module was at the last pattern the pattern will reset to the 1st pattern BACKUP PATTERN This function is only valid when the LED module is in a flashing mode disabled in cruise or steady ON functions When the light is flashing momentarily connect the white or yellow wire to ground for 1S and 2S light will go steady ...

Страница 5: ...OCATION 4X Ø 0 625 HOLE 2X PILOT HOLE LOCATION 2X 2 46 4 91 0 625 HOLE SINGLE SURFACE MOUNT TEMPLATE Important Printer Note From the print screen click on Actual Size in order for the template to print to it s proper dimensional size Verify dimensions are correct before using template to drill any permanent holes ...

Страница 6: ...olor Swap ON Color Swap OFF Color Swap ON Color Swap OFF Color Swap ON Cruise Cruise Color 1 Cruise Color 1 Cruise Color 2 Cruise Color 1 Cruise Color 2 Cruise Cruise Color 2 Cruise Color 1 Cruise Color 2 Cruise Color 1 Cruise Cruise Cruise Color 2 Cruise Color 1 Cruise Color 3 Cruise Color 3 Flash Flash Color 1 Flash Color 1 Flash Color 2 Flash Color 1 Flash Color 2 Flash Flash Color 2 Flash Colo...

Отзывы: