INSTALLATION:
SURFACE MOUNT
1) Establish a position on the vehicle. Use the
gasket (provided) as a template to drill 1/4”
diameter wire hole and pilot holes for mounting
screws. Note: pilot holes are 4.91” on center.
Caution: Do not stretch gasket as this may
change the required hole spacing.
SAE J595 CLASS 1 SURFACE MOUNTS
ENFSSS(XX)- SINGLE
ENFDSS(X)(XX) - DUAL
TECHNICAL SPECIFICATIONS
SURFACE MOUNT nFORCE
Single Mount
Dimensions:
5.0”L x 1.72”H x 1.50”D
Double Mount
Dimensions:
5.0”L x 3.13”H x 1.50”D
Input Voltage:
10 - 16 Vdc or 10 - 30 Vdc*
CURRENT CONSUMPTION
10-16 Vdc
10-30 Vdc *
6 LED Single
12 LED Dual &
18 LED Tri-Color
<1.0A @12.8 Vdc
<0.6A @ 25.6 Vdc
9 LED Single Color
<1.5A @ 12.8 Vdc
<0.9A @ 25.6 Vdc
12 LED Single Color
<2.0A @12.8 Vdc
<1.2A @ 25.6 Vdc
* - Special Order
GASKET
HOUSING
LIGHT ASSEMBLY
SINGLE MOUNT VERSION - DOUBLE MOUNT
VERSION NOT SHOWN
BACK VIEW OF SINGLE SURFACE MOUNT SHOWN W/O
RUBBER MOUNTING GASKET
- TYPICAL FOR BOTH VERSIONS-
DO NOT DAMAGE, BLOCK OR
TOUCH THE BREATHER PATCHES
MAKE SURE DRAIN
HOLE IS FACING DOWN
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
www.soundoffsignal.com/sales-support
. If you have questions regarding this product, contact
Technical Services
, Monday - Friday, 8 a.m. to 5 p.m. at
1.800338.7337
(press #4 to skip the
automated message). Questions or comments that do not require immediate attention may be emailed to
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
•HIGH CURRENT interconnects must be properly terminated. Poor crimp quality can cause heat
build-up and fire. Follow crimp connector manufacturer instructions.
•DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to vehicle
Owner’s Manual for deployment zones.
•Unit may become hot to touch during normal operation.
•Failure to properly install connectors, fuses or wiring may cause vehicle failure or fire.
•Installation must only be performed by trained technician. Installer must determine vehicle wiring
configuration and proper integration of system.
•Use proper wire gauge. All power wires connecting to positive (+) or negative (-) battery terminal
or local chassis ground (-) must be sized to supply at least 125% of max. current and properly fused at
power source.
•Install protective grommets when routing wire through firewall or metal.
WARNING
WIRE HOOK-UP TABLE
WIRE COLOR:
FUNCTION:
ORANGE OR RED
Power
BLACK
Ground
BLUE OR GREEN**
Sync2 *
YELLOW OR WHITE
to GROUND
Wire Function
-See page 4-
YELLOR OR WHITE
to POWER
Function Wire
RED/WHITE OR
ORANGE/WHITE
Power
** To sync multiple nFORCE lights, connect
the Green and/or Blue wires from each light
together.
* Will NOT work w/ other sync products
such as Ghost, LED3, & Intersector.
BLACK
RED
WHITE
GREEN
SINGLE OR DUAL
LIGHT HEAD 1
BLACK
BLUE
ORANGE
YELLOW
DUAL
LIGHT HEAD 2
Sync
Set-up/Function
Sync
Set-up/Function
RED/WHITE
ORANGE/WHITE
+Vdc
A FUSE
5
+Vdc
+Vdc
A FUSE
5
+Vdc
+Vdc
A FUSE
5
+Vdc
A FUSE
5