Soundoff Signal nERGY bluePRINT ENGCC01241 Скачать руководство пользователя страница 2

EVCS_Central  Controller_ENGCC01241  5.16       

1.800.338.7337 / www.soundoffsignal.com

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at

www.soundoffsignal.com/sales-support

. If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. at 

1.800338.7337

 (press #4 to skip the

automated message). Questions or comments that do not require immediate attention may be emailed to 

[email protected].

SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.

2

The Central Controller processor stores and interprets the input and output configuration from the software

application and control outputs accordingly as well as monitors outputs for fault conditions.  The Central Controller is 

fully software configurable via PC Software app through USB connection. 

The central controller is the communication hub for other system components within the EV Control System allowing 

for:

•A communication port for lightbar

•A communication port for 14 button control panel

•A communication port for other control system devices

 

•Up to 5 remote nodes

 

•Input node

 

•Up to 2 200R siren amplifiers

The central controller allows for 24 outputs for connection

to vehicle devices (100 Amps max) and has:

•(4) 10-amp fused outputs - constant power [outputs 11-14]

•(8) 10-amp solid state switchable outputs

•(12) 5-amp solid state switchable outputs

Multi-color lights should be driven by outputs within the same output group (Group 1: 1-5, Group 2: 6-10, Group 3: 

15-19, Group 4:20-24) to align timing.

Fault Condition Wink Patterns:

1 Wink - CPDU output(s) are faulted

2 Winks - Communication Fault

3 Winks - Source voltage level is < 9 VDC

4 Winks -  Source voltage level is > 16VDC

5 Winks - Over temperature condition

6 Winks - RPDU output(s) are faulted

CENTRAL CONTROLLER

PART NUMBER: ENGCC01241

See attached Install Template to aid in connections and programming

        

•Install fuse or breaker (100Amps max.) on main power supply.
•Do NOT connect product to strobe power supply.  Product is self-contained; no external power supply   
  needed.
•Follow attached Wiring and Interconnect requirements.

Torque the provided M8 nuts with lock washer to a maximum of 7ft-lbs.

   -Verify that the lockwasher is fully seated when assembled- 

WARNING

Tech Specs

nERGY Control System 

Central Controller

Input Voltage:

10-16Vdc (Negative Ground)

Maximum Load Current:

100 Amps

Outputs (Sum of ALL used Out-

puts Shall Not Exceed 100Amps)

4x 10Amp Fused Battery
8x 10Amp Solid State, Switched
12x 5Amp Solid State, Switched

IGN ON: Standby Current:

140mA

IGN OFF: Sleep Current:

0.34mA

Inputs:

1x Ignition Input Active High

Reverse Polarity Protection:

Not Protected (Reverse Polarity will 
Destroy the Devices)

Transient Protection:

Protected

High Voltage Protection:

>16V; High Voltage Error Code Set

Low Voltage Protection:

<9V; Low Voltage Error Code Set

Operating Temp:

-40˚C to + 65˚

C

Dimensions:

7” x 6.25” x 1”

Weight, Boxed:

1 lb. 7 oz.

Weight, Device Only:

14.9 oz.

Valid Integration Threshold - High

>8.5V

The Central Controller is not waterproof.  Install in a protected location 

away from excessive heat and moisture.

DIAGNOSTIC LED

•Power LED is steady on when the device is powered up and running with no errors.

•Power LED is off when the device is off or in sleep mode.

•Power LED winks when there is a system fault.

 

•Fault condition is read by counting the number of times the LED “winks”on.   

                   

                     Each fault condition will generate a pattern where each wink is 250ms off/250ms on.

                     The pattern is terminated by the LED being off for 2.5 seconds.

 

*The LED will wink multiple patterns when more than one fault condition is active.

Отзывы: