For a correct operation of your SounDigital amplifier, it is necessary to properly size
the electrical system and the cables used.
In the table below you can determine the minimum proper section of the
grounding, po 12VDC, and audio output cables according to the amplifier
power.
For the connections from the battery to the amplifier and to ground, use good
quality copper cables.
CCA cables should not be used.
POSITIVE CABLE (+12VDC)
NEGATIVE CABLE (GND)
AUDIO OUTPUT CABLE
1200
WRMS
16mm² - 5 AWG
2 x 2mm² - 12 AWG
RCA AND HIGH INPUTS SHOULD NOT BE USED SIMULTANEOUSLY OR YOU MAY
DAMAGE THE AMPLIFIER.
Warning!
High input must be used when the main unit does not have RCA outputs.
When hi inputs is used, no remote connection is required, the amplifier recognizes
the audio signal and switches on.
If your source unit is not able to turn on the amplifier through the high level input, the
remote input should be connected normally.
All RCA Inputs must be connected for
the 2 channels work, including the Bridge
Connection
All High Signal Inputs must be connected for
the 2 channels work, including the Bridge
Connection