If you would like to switch your mic to multi-pattern operation:
E47 Pattern Change Directions from Fixed to Variable
[Single Capsule vs. Dual Capsule Operation Modes]
1.
Remove 3 screws that hold headgrille assembly to body assembly. Remove the headgrille assembly, which contains the
capsule.
2.
Remove single screw that holds the body tube in place. Pull the body tube from the body.
3.
See metal plate with 2 position switch above vacuum tube area. Flip switch the other way (forward) for variable pattern
(dual capsule mode) or backward for Fixed Cardioid (single capsule mode). The words “Variable Pattern” and “Cardioid”
are printed on the circuit board.
4.
Replace the body tube, replace screw.
5.
Install Headgrille assembly by slightly tilting Headgrille backward so the guide pin goes into the guide pin hole, then insert
the connector on the headgrille to the socket on the top of the body, re-install the 3 screws that hold the headgrille to the
body.