10
ELECTRICAL DIMENSIONING AND AUDIO INPUTS
ELECTRICAL DIMENSIONING
For proper operation of your SounDigital amplifier, you need the proper
dimensioning of the electrical system and the cables used.
The table below shows the minimum section of GND cables, +12VDC cables and
speaker output cables according to the power generated by the amplifier.
We recommend the use of ONLY OFC (Oxygen Free Copper) Cables on the
installation of our products.
AUDIO INPUTS
RCA AND HIGH INPUTS SHOULD NOT BE USED SIMULTANEOUSLY OR YOU MAY
DAMAGE THE AMPLIFIER.
Warning!
High signal inputs
RCA Inputs
X
X
All RCA Inputs must be connected for
the 4 channels to work.
All High signal Inputs must be connected for
the 4 channels to work.
High input must be used when the main unit does not have RCA outputs.
When hi inputs is used, no remote connection is required, the amplifier recognizes
the audio signal and switches on.
If your source unit is not able to turn on the amplifier through the high level input, the
remote input should be connected normally.
POWER CABLE
GROUND CABLE
SPEAKER CABLE
1200
WRMS
16mm² - 5 AWG
Содержание EVOX 1200.4
Страница 1: ...1 OWNER S MANUAL 1200 4 ...