V1.22
Owners Manual SP20-Linex™
- 32 -
5. Array configuration
The WLL of the flying frame and cabinet rigging is given for a straight ‘dead-hang‘ array. The
maximum number of cabinets allow in other situations is given by the SPArC™ software. The
following table gives an indication of the maximum number of cabinets.
Flying Frame angle = 0 degrees
Indicative*
maximimum
no. of cabinets
av.
angle
max.
angle
flyframe
J-shape**
C-shape***
0
8 deg.
24
24
1
4 deg.
24
24
2
0 deg.
24
20
3
0 deg.
20
16
4
0 deg.
16
14
5
0 deg.
14
12
6
0 deg.
10
10
*
Always consult SPArC™ for the maximum no. of cabinets
**
J-shape: the lower half of the array has a larger angle setting than the upper half. No
angle of a cabinet is higher than a lower cabinet.
***
C-shape: all angle settings between cabinets in the array are the same.
Note: When using SPArC™ it will automatically indicate when the maximum workload of a
configuration is exceeded. When the maximum number of cabinets without the satisfactory
result it is possible it can be achieved by changing the configuration: for example in most cases
lowering the array will tilt the array to a more neutral axis allowing more cabinets in the array.