TUBE VITALIZER

Selection of two bass timbre
(Soft – Tight) and adjusting
the intensity

Varying bass sounds 
by balancing Bass and
Process Level

Adding a passive LC filter
network to the bass filtering
system

This easy-to-use compressor
works exclusively on the bass
and helps you to control the
bass amplitude especially
when recording on digital
media

The Gain Reduction LED indi-
cates compressor operation

They symbolize the contoured “Tight” bass sound. If the Bass
control is moved from the center position (0) to the left, the bass
sound becomes very deep, soft and warm. This sound is known as
“Soft”. This is symbolized with round scaling points which also
increase in size as the intensity increases.

The further the Bass control is shifted to the right or left of the

center position, the more intensive the bass sound in question.
However, Process Level (7) must be positioned to the right of the
9 o´clock setting for the bass to be audible. You can always hear
the original (dry) bass if the Bass control is in the center position.
The Process Level control determines the processing ratio
between the set bass sound colour and the original signal. This
results in varying bass sound structures: if you combine high bass
amplification on the Bass control with a lower Process Level
value, you get a different bass structure than with a lower bass
amplification combined with a higher Process Level value.
Choosing the best solution is a matter of personal taste and also
depends on the type of original signal involved.

The active filter-network to process the bass operates with a

RC-combination (R = resistor; C = condenser). The LC Filter switch
adds a passive coil/condenser filter to the network.

Coils are known for their pleasant sound. When getting satu-

rated they produce a special harmonical structure giving a
certain punchy sound that we know from old filter designs. The
Tube Vitalizer offers you the choice between both ‘worlds’.

The Tube Vitalizer features a compressor, which is integrated

into the bass filter network. The original signal is left untouched.
When recording on digital equipment it is essential not to over-
load the inputs of such systems which results in invalid samples
or digital peaks. As the bass frequencies carry most of the level it
makes sense to integrate a compressor into the bass-path. This
compressor works with a soft-knee characteristic. We designed
the compressor around the well acclaimed THAT 4301 VCA as a
‘one-knob’ solution to make it easy to operate. The threshold,
attack and release are automatically adjusted. The Compression
control sets the ratio value.

The blue Gain Reduction LED indicates the point at which the

compressor starts to operate. When you turn the Compression
control fully clockwise the entire bass processing is nullified.

Control elements

Bass – LC Filter

4

Bass Comp.

5

Содержание TUBE VITALIZER 9530

Страница 1: ...Model 9530 Manual Program Equalizer TUBE VITALIZER ...

Страница 2: ...e liable for any damages including loss of data lost profits cost of cover or other special incidental consequential or indirect damages arising from the use of the unit however caused and on any theory of liability This limitation will apply even if SPL or an authorised dealer has been advised of the possibility of such damage SPL electronics GmbH Postal address P O Box 12 27 D 41368 Niederkruech...

Страница 3: ...8 Video Film Post Production 9 First Steps 10 Control Elements Activate Process 1 11 Drive 2 11 Bass 3 11 Bass LC Filter 4 12 Bass Comp 5 12 Hi Mid Freq 6 13 Process Level 7 15 High Freq 8 16 Intensity 9 16 High LC Filter 10 17 High Comp 11 17 Activate Tubes 12 18 Attenuator 13 18 Atten Limit 14 19 VU In Out 15 19 Tube Status 16 19 Power Supply 20 Specifications 21 Warranty 22 ...

Страница 4: ...ca tions and by our customers themselfs and constantly valued with best results I would like to pass on this broad appreciation to those who deserve it my excellent colleagues Hermann Gier Foreword Thanks The housing of the Tube Vitalizer has the standard 19 EIA format and occupies 2U 88 mm in your rack The Tube Vitalizer should not be installed near units which produce strong magnetic fields or e...

Страница 5: ...ange The bass is accentu ated without any risk of emphasizing the lower mid frequencies unnaturally You can choose between a dry percussive bass Tight or a punchy soft and very deep sound character Soft Both sounds can be altered by adding a passive LC filter network The bass and high frequency section are both equipped with easy to use compressors based around the THAT 4301 The output section can...

Страница 6: ...t the same time or split the output between a mixer and effects processor However only one type of input jack or XLR should be connected at a time the Tube Vitalizer is not intended to be used as a mixer To ensure optimal signal quality SPL has developed a new hybrid component balanced input output stage using all laser trimmed resistors with a tolerance of 0 01 This approach has resulted in an ex...

Страница 7: ...on of the master fader does not affect the input level of the Tube Vitalizer The effect level and the treated sound will then remain unchanged It is important to use full range monitors to assess the full effect of any bass processing in and out of circuit in order to appreciate just how much processing has been added the brain soon accli mates to changes in timbre and it is easy to overdo it If i...

Страница 8: ...en and enrichen dialogue even when the microphone placement is less than optimum as is often the case when filming due to the need to keep the mic out of shot Music soundtracks benefit in the ways already described for audio only applications and the fact that the Tube Vitalizer is so quick to set up can save a lot of wasted time spent tuning multi band equalizers Time compressed audio can also be...

Страница 9: ...dds a passive LC filter to the RC filter network resulting in an even punchier bass sound 4 Now start varying Hi Mid Freq The original setting is 3 5 kHz Turn to the right The programme material sounds brighter and gets more mids from about 1 5 kHz The Hi Mid Freq control sets a starting frequency above which all frequencies are processed If this starting frequency is lowered the frequency spectru...

Страница 10: ...h over These may become apparent as audible click sounds If applicable reduce or mute the monitor loudspeakers before switching on or off The Tube Vitalizer features a Drive control that enables you to set the level at which the Vitalizer filter network operates The level can be changed between 20dB and 6dB To run the unit hotter set the level between the center position 0dB and the clockwise posi...

Страница 11: ...structure than with a lower bass amplification combined with a higher Process Level value Choosing the best solution is a matter of personal taste and also depends on the type of original signal involved The active filter network to process the bass operates with a RC combination R resistor C condenser The LC Filter switch adds a passive coil condenser filter to the network Coils are known for the...

Страница 12: ...en broad band frequencies are raised The Hi Mid Freq filter can raise the broad band spectrum with a very linear frequency response without colouring the signal Above the Hi Mid Freq value set the Tube Vitalizer filters create a linear increase i e one that is adapted to the human ear This compensates any inability of our hearing as regards perceiving frequencies ranging between 5 kHz and 10 kHz T...

Страница 13: ...cess Level Max Hi Mid Freq 1 1 5 2 5 3 5 8 14 22 kHz Measurement 3 Bass Soft Bass LC filter Off Process Level Max Hi Mid Freq 1 1 5 2 5 3 5 8 14 22 kHz Measurement 4 Bass Soft Bass LC filter Active Process Level Max Hi Mid Freq 1 1 5 2 5 3 5 8 14 22 kHz Control elements ...

Страница 14: ...s maintained between all frequency ranges even at varying monitor volumes For the human ear the sound is more pleasant and easier to perceive than the original In other words increasing the Process Level value also increases the intensity of the Hi Mid Freq filter and the Bass filter whilst domi nant mid frequencies are damped by amplitude controlled phase shiftings This improves the perception of...

Страница 15: ...on any more The Hi Mid Freq and the High Freq filter complement each other in an ideal fashion While the Hi Mid Freq sets the frequency above which the program material is lifted and below which the damping takes place the High Freq and Intensity controls come in place to extract certain frequencies from this process This is very helpful when you are processing material with lead vocals Using the ...

Страница 16: ...ube section provides a frequency bandwidth from 30 Hz to 30 kHz Standard designs often limit the bandwidth which gives a frequency band limiting impression that is often associated with tube sound Vitalizer s tube sections does not limit the frequency response If you carefully listen to the the reverb room of vocals or snare or simply put on pink noise you can best identify the tubes additional ha...

Страница 17: ...nput or output levels to be displayed on the VU meters When the status LED is not illuminated the VU meter will show the input levels On the other hand an illuminated status LED indicates that the output level is displayed The 0 dB mark on the VU is internally calibrated to 6 dB The Tube Vitalizer features a special relay circuitry that slowly builds up the 250 volts over a period of 45 seconds Th...

Страница 18: ...ector for a detachable power cord enclosed with an inbuilt mains filter Transformer power cord and mains connector have VDE UL and CSA approvals The fuse has a value of 315 mA for the primary voltage and 500 mA for the secondary when operated at 230 V 50 Hz At 115 V 60 Hz the fuse value for the primary voltage is 800 mA and for the secondary voltage 1000 mA 1A On the secondary side of the power su...

Страница 19: ... Frequency response without tubes 10 Hz 100 kHz 100 kHz 3 dB Frequency response with tubes 30 Hz 100 kHz 30 kHz 3 dB CCMR common mode rejection 100 dBu at 1kHz THD N 0 002 at 1kHz S N CCIR 468 3 83 dBu S N A weightened 89 dBu Power Supply Toroidal transformer 35 VA Fuse primary 500 mA 230 V 50 Hz 1000 mA 115 V 60 Hz Fuse secundary 315 mA 230 V 50 Hz 630 mA 115 V 60 Hz Ground Lift switch Voltage se...

Страница 20: ...thorized SPL warranty repair facility in the country where purchased or to the SPL factory in Germany in the original packaging or a replacement supplied by SPL with all transportation costs and full insurance paid each way by the purchaser or owner All remedies and the measure of damages are limited to the above services It is possible that economic loss or injury to person or property may result...

Отзывы: