Sound Performance Lab 2048 Скачать руководство пользователя страница 5

5

Hookup

• Three fully parametric bands in accordance with the musically effective

proportional-Q-principle, Boost/Cut +/- 15 dB, Q 0.5 to 5; LOW band:10-250
Hz, MID band: 140 Hz-3,5 kHz, HIGH band: 940 Hz to 24 kHz.

• Sub-Bass-EQ (Cut/Boost +/- 14 dB, up to 200 Hz) with coil/capacitor filter

network that produces a penetrating and lucid deep tone spectrum. The
combination of Sub-Bass and Low filter for the processing of the bass
spectrum is very effective and opens a new dimension for sound creations.

• Air-EQ: the selected coil/capacitor-filter network provides a silky and airy

presence – especially in digital recording.

• The 3D-Enhancer intensifies the spatial impression of the stereo signal

without affecting the low frequency tonal components.

• Optional provision of input and output transformers from Lundahl: balan-

cing through transformer stages; the galvanic separation ensures high
operational safety. Tonal advantages are offered by the transformer coil.
This minimizes odd harmonic distortion and provides a silky top end.

• Generally coils sound less aggressive, but produce a rounder and more

powerful sound in the deep tone spectrum. This means they possess
advantageous musical properties which is why SPL prefers to install coils
in the filter area.

• Ground: Disturbances which could have an effect over the ground-runs

are minimized by the separation of the audio-ground from that of the
remaining apparatus. This leads substantially to a higher and ‘cleaner’
tonal quality (in the strictest sense of the word).

• Power supply: The  toroidal transformer forms the basis for a clean power

supply throughout the circuitry.

Carefully select a place for setting up the Stereo Q. The unit should be
situated away from heat sources and direct sunlight. Avoid installation in
environments exposed to vibrations, dust, heat, cold or moisture. Keep the
unit away from transformers or motors or any other unit that could generate
large variations in power supply or cause electrical interferences. Do not
install the unit in proximity to power amplifiers or digital processors. You
may consider placing it in a rack containing other analog gear. Such place-
ment can prevent interference from  Word Clock, Smpte, MIDI, etc.

• Do not open the case. You may risk electric shock and equipment damages.

• Leave repairs and maintenance to a qualified service technician. Should 

foreign objects fall inside the case, contact your authorized dealer or sup-
port person.

• To avoid electric shock or fire hazards do not expose your unit to rain or 

moisture.

• In case of lightning unplug the unit. Please unplug the cable by pulling on 

the plug only; never pull on the cable. Never force a switch or knob.

• To clean the case use a lint-free cloth. Avoid cleaning agents as they may 

damage the chassis. Manufactured in standard 19" EIA format, it utilizes two 
rack units.

• Please support the back of the unit whenever it is being mounted into a 19" 

rack (especially important when touring).

Features

Содержание 2048

Страница 1: ...Model 2048 Manual Parametric 5 Band Stereo Equalizer ...

Страница 2: ...orization of SPL Limitations of Liability In no event will SPL be liable for any damages including loss of data lost profits cost of cover or other special incidental consequential or indirect damages arising from the use of the unit however caused and on any theory of liability This limitation will apply even if SPL or an authorized dealer has been adviced of the possibility of such damage Sound ...

Страница 3: ...ront wiring 6 General advices sockets 7 Operation General Advice Proportional Q recommendations for the setting of bandwidth Q 8 Power 9 Active 9 Sub 9 Low 10 Mid 11 High 11 Air 12 3D Enhancer 12 Power Supply 13 Specifications 13 Warranty 14 Copy Master 15 Notes 16 ...

Страница 4: ...ng adjustments could cause unsui table correlations of the stereo program the correction of which is very complicated The close adjustment tolerances of the Stereo Q reliably avoid this problem which makes it an extremely suitable unit for inclusion in a 5 1 surround studio where the need for coherent twin matching of both chan nels front L R or surround L R is paramount Even small and medium size...

Страница 5: ...from that of the remaining apparatus This leads substantially to a higher and cleaner tonal quality in the strictest sense of the word Power supply The toroidal transformer forms the basis for a clean power supply throughout the circuitry Carefully select a place for setting up the Stereo Q The unit should be situated away from heat sources and direct sunlight Avoid installation in environments ex...

Страница 6: ...3 1 GND 2 hot 3 cold 1 2 3 Pin wiring XLR output Pin wiring XLR input 1 GND 2 hot 3 cold Pin wiring stereo jack connectors Tip hot Ring cold Sleeve GND Console outputs insert sends Guitar amp Keyboard Sampler Stereo mic preamp All stereo signals or 2 x Mono Inputs XLR or Jack Outputs XLR or Jack ...

Страница 7: ...nnected with mono Jack connectors to the balanced Jack sockets Generally all stereo signal equipment can be connected to the Stereo Q The diagrams on page 6 show various examples and their method of connec tion whether by XLR or Jack connectors It is of course possible to process mono signals either singly or in pairs if identical processing is required In order to keep the purest signal quality i...

Страница 8: ...width relates to approximately 0 2 octaves on the Stereo Q the minimum Q value 0 5 greatest bandwidth is approximately 2 octaves Bandwidth adjustment is always dependant on the program or instruments to be used It is not possible to lay down hard and fast rules but the following recommendations are provided Q values between 1 and 2 are as a general rule most suitable for proces sing of voices keyb...

Страница 9: ...low under all circumstances Active Active switches the electronics via the hard bypass relais into the signal path The button switches a crackle free relay and offers a fast comparison between the processed and unprocessed signal To protect the entire elec tronic circuitry the Active switch should be used when the unit is deac tivated for a short period The power switch should only be used when th...

Страница 10: ...powerful bass foundation with clear definition impure bass equalization is eradicated Low The Low filter spans the frequency range of 10 to 250 Hz Frequency control It can be described as a decisive low band filter that in distinction to many comparable concepts deals exclusively with the low tonal range and in this manner can be utilized very accurately and with high sensitivity The maximal ampli...

Страница 11: ...setting of bandwidth on page 8 High The High filter spans the frequency range from 940 Hz to 24 kHz Frequency control The High filter is utilized in the first place for narrow band corrections whether to eliminate interference frequencies e g pilot reference or to accentuate certain frequencies The combination of High and Air band offers excellent possibilities for the processing of the high frequ...

Страница 12: ... restoration and tonal improvement of old recordings This in combination with the High filter provides extensive possi bilities for processing the top end With the Air filter a brilliant top end can be produced over which the High filter can superimpose frequency selective accents 3D Enhancer The 3D Enhancer serves the expansion of the stereo base The circuitry recognizes the signal components tha...

Страница 13: ...onnector Transformer AC cord and IEC receptacle are VDE UL and CSA approved The main fuse is rated at 315mA Chassis ground and AC ground can be physically disconnected by the Ground Lift switch GND LIFT This helps to eliminate hums Input Output Instrumentation amplifier electronically balanced differential transformerless Nominal input level 6 dB Input impedance 22 kOhms Output impedance 600 Ohms ...

Страница 14: ...uthorized SPL warranty repair facility in the country where purchased or to the SPL factory in Germany in the original packaging or a replacement supplied by SPL with all transportation costs and full insurance paid each way by the purchaser or owner All remedies and the measure of damages are limited to the above services It is possible that economic loss or injury to person or property may resul...

Страница 15: ...15 Copy Master Production Artist Date Sound Engineer ...

Страница 16: ...16 Notes ...