Sound City SC 20 Скачать руководство пользователя страница 11

11

© 2018 Sound City® Amplification. All rights reserved. Specifications subject to change without notice.

CERTIFICATE OF COMPLIANCE AND CONFORMITY

Certificate of Compliance

Restriction of the use of Hazardous Substances  (RoHS)

We certify that all of our products (exceptions see listed below) are compliant with the European Union Directive 

2002/95/EC for the Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 

(RoHS). 

No Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent Chromium (Cr+6), PBB or PBDE is intentionally added 

to these devices. Any trace impurities of these substances contained in the parts are below the RoHS specified 

threshold levels. 

All information provided in this Certificate of Compliance is accurate to the best of our knowledge as of the 

date this Certification was issued. 

Certificate of Compliance

Registration, Evaluation, Authorization and Restriction  

of chemicals (REACh)

We declare that all of our products are compliant with European Union Directive EC1907/206 for the Registration, 

Evaluation, Authorization and Restriction of chemicals (REACh), and contain none or less than 0.1% of the 

chemicals listed as hazardous chemicals in the REACh regulation. All information provided in this Certificate 
of Compliance is accurate to the best of our knowledge as of the date this Certification was issued.

Declaration of Conformity

EMC and Low Voltage Directive (CE)

Product Name: 

SC20 Combo

Model Number: 

SC20C

This is to certify that the product listed above complies with the following European Union Council Directives 

and Standards relating to electromagnetic compatibility (EMC Directive 89/336/EEC) and the low voltage 

Directive (73/23/EEC).

This declaration of conformity of the European Communities is the result of an examination carried out by 

Electromagnetic Engineering Services, Inc. in accordance with European Standards EN 50081-1, EN 50082-1 

and EN 60065 for low voltage, as laid down in Article 10 of the EMC Directive.

Group Eleven, LLC.

6850 Vineland Ave. Unit P

North Hollywood, CA 91605 USA

Содержание SC 20

Страница 1: ...OWNERS MANUAL SC 20 www soundcityamp com ...

Страница 2: ...launch the big sound revolution in 1967 The SC20s sparking tonal palette comes courtesy of a matched pair of Mullard 6V6 power tubes producing a rich natural sustain topped off with the instantly recogni zable tube driven Accutronics reverb Cranking up the volume pushes the power tubes into blissfull overdrive Simply stated you ll find the full bodied performance of the Sound City SC20 tube combo ...

Страница 3: ...ne blade wider than the other This is a safety feature If you are unable to insert the plug into the outlet contact an electrician to replace your obso lete outlet Do not defeat the safety purpose of this plug X X Protect the power supply cord from being pinched or abraded X X The power supply cord of this product should be unplugged from the outlet when left unused for a long period of time or du...

Страница 4: ...trols set the input stage and power amp gain amount as you rotate the knobs clockwise The NORMAL volume feeds a full range gain stage the delivers deep low end and a subtle top end sparkle As you increase the volume the tonal balance develops a fatter smoother character This stage is ideal for dialing in a big dynamic punch that cleans up nicely when backing off on the guitar volume The BRILLIANT ...

Страница 5: ... tonal territory before you even begin to start thinking about tone control settings See page 9 for sample settings For guitars with humbuckers When using humbucking pickups with enhanced midrange output push the normal volume more than the brilliant volume For guitars with single coils When using single coil pickups push the brilliant volume more than the normal volume Different combinations of N...

Страница 6: ...l counter clockwise for crisp and articulate clockwise for thick and saturated 3 BRILLIANT VOLUME Sets the volume of the brilliant gain stage This first gain control also serves as a tone shaping control counter clockwise for clean and bright clockwise for snappy and mid focused EQUALIZATION SECTION Passive Interactive tone controls 4 TREBLE Passive High frequency equalization 5 MIDDLE Passive Mid...

Страница 7: ...12AX7A 12AX7A 12AX7A Tube locations from right to left looking at the back of the amp Tube types are factory selected for superior performance consistent tone quality and reliability While substi tuting other brands may not cause damage to the amplifier this may affect amplifier performance in unpre dictable ways For best performance replace only with factory recommended tubes Warning Substituting...

Страница 8: ...can actually withstand a much higher peak power when called upon to do so Every speaker requires a nominal break in period before it achieves its intended performance and this is true of the F50G For best results simply play the way you play and let the speaker break in according to your playing style and volume preference Each player has a different idea about how reverb should respond The SC20 r...

Страница 9: ...AL VOLUME INPUT SOUND CITY SC20 Scuttle Buttin REVERB MAINS ON BASS MIDDLE TREBLE BRILLIANT NORMAL VOLUME INPUT SOUND CITY SC20 Day Of The Eagle REVERB MAINS ON BASS MIDDLE TREBLE BRILLIANT NORMAL VOLUME INPUT SOUND CITY SC20 Little Wing Freedom REVERB MAINS ON BASS MIDDLE TREBLE BRILLIANT NORMAL VOLUME INPUT SOUND CITY SC20 Little Wing For strat in middle bridge Pick up setting Freedom For strat ...

Страница 10: ...d replace if necessary If it blows again refer to qualified service personnel NO SOUND 1 Check input cable 2 Make sure the channel volumes are turned up 3 Check speaker cable to see if it is disconnected or shorted 4 Check for a blown speaker 5 Look at the preamp and power tubes to see if they are lighting up RUNNING HOT 1 Make sure that the unit has adequate ventilation 2 Make sure that the speak...

Страница 11: ...h We declare that all of our products are compliant with European Union Directive EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemicals in the REACh regulation All information provided in this Certificate of Compliance is accurate to the best of our knowledge as of the date this C...

Страница 12: ...ontrol of SCA including but not limited to any malfunction defects or failure caused by or resulting from unautho rized service or parts damaged or broken tubes incorrect line voltage improper maintenance modifica tion or repair by the user abuse misuse neglect accident fire flood or other Acts of God 5 Responsibility for the repair of any SCA product sold outside of U S boundaries is borne by the...

Отзывы: