- 39 -
SORHEA
G-FENCE
6.1 Procedure to enter into setting mode.
1) Check the cable whose sensitivity is to be adjusted. (cable 1 or cable 2)
2) Set the Link Unit (UR)
of the cable to be configured to “
UT
” mode.
3) Move the switch for cable 1 or cable 2 to enter configuration mode for the Control Unit (UG)
and configure the cable selection (cable 1 or cable 2).
The buzzer will emit 2 short beeps to confirm entry into configuration mode.
The red Led starts blinking.
4) The buzzer beeps once and the red LED goes off. Configuration is finished.
If after 2 minutes, the red Led is still blinking, refer to §8 MAINTENANCE.
6.2 Settings Mode
The Control Unit (UG) is configured in settings mode.
The selected parameters can be modified ones after the others with any particularly order.
Step 1: Select the function code thanks to the code selection wheel.
Example: code 99
Step 2: Adjust the potentiometer.
Step 3: Press the tamper protection switch, the buzzer rings for 5 sec.
Wait until the buzzer stops to move to the next step.
Hold the press during step 4.
Step 4: Press the push-button until a beep confirms that the parameter adjustment is taken into
account.
Tenth Digit
Single Digit
Code 99
UT/UR
Red LED