- 41 -
SORHEA
G-FENCE
6.3 Advanced Settings
The advanced settings allow setting of the sensitivity.
Note: Function only available on the cables serial number i
s greater than “7000”
(Example: S/N XXXXXX-7000-
…)
Parameter
code
Function
Process
Factory
setting
Step 1
Step 2
Step 3
Step 4
60
1 sample above the
detection threshold (*)
+
x
61
2 samples above the
detection threshold (*)
+
62
3 samples above the
detection threshold (*)
+
71
Sample rate : 10 ms (*)
Number of samples : 30
+
73
Sample rate : 20 ms (*)
Number of samples : 15
+
x
82
Level of filtering between the
axes : 2
+
83
Level of filtering between the
axes : 3
+
84
Level of filtering between the
axes : 4
+
x
85
Level of filtering between the
axes : 5
+
86
Level of filtering between the
axes : 6
+
Note: Parameters saved in the sensor memory
(*) Example:
Threshold
1 sample above the
detection threshold
2 sample above the
detection threshold
Sample rate