Local Operation
4-9
Press 0, then ENTER to set OFF time to 0 seconds. The default setting is 0
seconds for OFF time.
SEQ. OFF TIME
TIME: 0.00Sec
5. Setting the Sequence Mode
There are three modes to control the method of sequence execution.
•
SKIP: Skip the sequence. Load will not change input status.
•
AUTO: Use ON/OFF time to control Load input on/off. When ON/OFF time
passes, the Load will get to the next sequence automatically.
•
MANUAL: Use the
^
or
v
key or numbers 0 to 9 to control the execution
sequence. Pressing number keys allows random selection of sequence
numbers to execute. Pressing 0 means to go to sequence 10.
Press 2, then ENTER to set sequence 1 to manual mode. You must set ten
sequence settings for one program. The default setting is SKIP.
SEQ
1:
SKIP=0
AUTO=1 MANUAL=2
6. Setting the Short Channel
When the sequence mode is not SKIP, you must set the short channel and time.
The short channel is selected as an active channel. To select the short channel,
press numbers 1 through 8 to enable or disable the corresponding module’s short
function.
SEQ. 1 SHORT CH.
1
3
5
6 7
8
7. Setting the Short Time
The short time range is from 0 to 30 seconds. The short time must be
≤
SEQuence ON time. If the short channel is not selected, or the short time is set to
0 seconds, the selected channel will not short. The default setting is channel 0
and 0 seconds.
SEQ. 1
SHORT TIME= 0.0S