Installation

MD Remote Option 

(includes plundger, 20 foot cable and two crimps.)



  Screw plunger to the top of unit.

  

  Thread the 20’ cable through the hole in plunger and create a 14 inch top loop as 

shown below. 

  



At the bottom of the cable, a second loop can be created as a handle for actuation at 

the desired length.

The unit may be mounted in any of the following installation arrangements:



  1-1/2” NPT half coupling (No full coupling).



  2” NPT full coupling. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)



  2” NPT pipe tee. (Use in conjunction with 2 x 1-1/2” NPT bushing as required.)



  Optional flanged mounting.



  Optional chamber mounting. 

Linear = mm/inches

Drawing 0098636

REMOTE MANUAL CHECK

MD OPTION

CRIMP

 

REMOTE CABLE 

 

 

CREATE HANDLE AT DESIRED LENGTH

 

 

TOP 14” LOOP

 

 

PLUNGER

Содержание 1510

Страница 1: ...meplate instructions shown here NOTE If you suspect that a product is defective contact the factory or the SOR Representative in your area for a return authorization number RMA This product should only be installed by trained and competent personnel 1510 Side Mounted Level Switch General Instructions NC indicates circuit is closed Registered Quality System to ISO 9001 Design and specifications are...

Страница 2: ...andle for actuation at the desired length The unit may be mounted in any of the following installation arrangements 1 1 2 NPT half coupling No full coupling 2 NPT full coupling Use in conjunction with 2 x 1 1 2 NPT bushing as required 2 NPT pipe tee Use in conjunction with 2 x 1 1 2 NPT bushing as required Optional flanged mounting Optional chamber mounting Linear mm inches Drawing 0098636 REMOTE ...

Страница 3: ...he shaft Float Attachment Series 1500 with Flange Safety Integrity Level SIL Installation Requirements The SOR pressure switches have been evaluated as Type A safety related hardware To meet the necessary installation requirements for the SIL system the following information must be utilized Proof Test Interval shall be one year Units may only be installed for use in Low Demand Mode Products have ...

Страница 4: ... model number Linear mm inches Drawing 0390760 177 8 7 00 55 6 2 19 14 3 0 56 79 0 REF 3 11 31 5 1 24 MAX 53 8 2 12 FLOAT TRAVEL 22 2 WRENCH FLATS 0 87 FLOAT 1 1 2 NPTM PROCESS CONNECTION OR FLANGE MOUNTING NOT SHOWN BODY 1 2 NPTF ELECTRICAL CONNECTION WIRE LEADS 457 2 18 00 MIN LENGTH COLOR CODED AND MARKED 44 5 WRENCH FLATS 1 75 1 NOTES 1 ACTUATE DEACTUATE POINTS VARY OPERATES 56 4 SATISFACTORIL...

Страница 5: ...e permanently attached leads must be suitably protected against mechanical damage and terminated in a suitable junction box or terminal facility Ensure that the wiring conforms to all applicable local and national electrical codes and install unit s according to relevant national and local safety codes Electrical connection is free wire leads with a 1 2 NPT F conduit connection Use two wrenches on...

Страница 6: ... 1 2007 04 IEC 60079 11 2011 IEC 60079 25 2010 02 IEC 60079 0 2004 IEC 60079 11 1999 ATEX Listing Information Drawing 0720554 Manufacturer s Registered Trademark Product Type Identification Product Model Identification For Type 1510 Level Switches equipped with DPDT relays a wiring schematic and pin position schematic is shown below When the 1510 is actuated the coil will energize and make both NO...

Страница 7: ...ectric Switches SOR Inc 14685 West 105th Street Lenexa Kansas 66215 2003 5NITED 3TATES OF MERICA December 18 2017 4 8 IRECTIVE 5 QUIPMENT NTENDED FOR USE IN 0OTENTIALLY XPLOSIVE TMOSPHERES 4 8 ARKING X ARKING II 1 G Ex ia IIC Ga Ex ia IIC Ga 4 d 4A d OR 4 d 4A d OR 4 4A 4 4A II 2 G Ex db IIC Ga Gb Ex db IIC Ga Gb 4 d 4A d OR 4 d 4A d OR 4 4A 4 4A EC Type Examination Certificate Baseefa06ATEX0271X I...

Страница 8: ... float Replace Liquid specific gravity too low Float stem bound up or dirty Clean Part Number Description 3130 052 316SS Float Assembly 3130 106 W9 SPST Hermetically Sealed Switch Capsule 3130 245 W1 SPDT Hermetically Sealed Switch Capsule 3130 259 W1 SPDT Switch Conduit Connection Assembly CK Option Only 3130 107 L9 SPST Hermetically Sealed Switch Capsule 3130 244 L1 SPDT Hermetically Sealed Swit...