General server precautions

 

Ì

 Review the electrical and general safety precautions that came with the 
components you are adding to your appliance.

 

Ì

 Determine the placement of each component in the rack before you install 
the rails.

 

Ì

 Install the heaviest server components on the bottom of the rack first, and 
then work up.

 

Ì

 Allow hot plug hard drives and power supply modules to cool before 
touching them.

 

Ì

 Always keep the rack‘s front door, all panels, and server components 
closed when not servicing to maintain proper cooling.

Rack mounting considerations

 

Ì

 Ambient operating temperature: 

If installed in a closed or multi-unit rack 

assembly, the ambient operating temperature of the rack environment 
may be greater than the ambient temperature of the room. Therefore, 
you should install the equipment in an environment compatible with the 
manufacturer’s maximum rated ambient temperature. 

 

Ì

 Reduced  airflow:

 Equipment should be mounted into a rack so that 

airflow required for safe operation is not blocked.

 

Ì

 

Mechanical loading:

 Equipment should be mounted into a rack so that a 

hazardous condition does not arise due to uneven mechanical loading.

 

Ì

 

Circuit overloading: 

Follow the equipment nameplate ratings to avoid 

possible circuit overload.

 

Ì

 Reliable  grounding:

 Reliable grounding must be maintained at all times. 

To ensure this, the rack itself should be grounded. Particular attention 
should be given to power supply connections other than the direct 
connections to the branch circuit (i.e., the use of power strips, etc.).

Rack mounting instructions

To mount the appliance to the rack you need the included rack-mount 
brackets and rails. There are a variety of rack units on the market, which may 
mean the assembly procedure will differ slightly. You should also refer to the 
installation instructions that came with the rack unit you are using.

Because of the dimension and weight the model Astaro Security Gateway 
625 is delivered with a special rail kit. The chassis package includes two rail 
kits. Each kit consists of two pieces: a short inner rail and a long outer rail. 
The inner rail has six round holes and two fastenings. The outer rail has long 
ovals.

Содержание Astaro 625

Страница 1: ...Operating Instructions Astaro Security Gateway 625 ...

Страница 2: ...The following symbol and its meaning appears in the Hardware Quick Start Guide Security Notes and in these Operating Instructions Caution and important note If these notes are not correctly observed Ì Ì This is dangerous to life and the environment Ì Ì The appliance may become damaged Ì Ì The functions of the appliance will be no longer guaranteed Ì Ì Shall be liable for damages arising from a fai...

Страница 3: ... compliant parts may be used Maintaining CE and FCC compliance also requires proper cable and cabling techniques 5 Operating elements and connections Astaro Security Gateway 625 rev 1 LED power hard disk power fail COM reset button 10 x 10 100 1000 Base TX ports 8 x SFP GBIC ports buzzer reset button power supply RAID hard disk system hot swappable redundant power supply hot swappable fans power s...

Страница 4: ...ve not been loaded or do not function correctly Activity LED Yellow Flashing The adapter is sending or receiving network data The frequency of the flashes varies with the amount of traffic Off No activity LCD and control keys The Astaro Security Gateway 625 has an LCD and an operating unit with four membrane keys In the LCD 16 characters per line can be displayed The display contains information o...

Страница 5: ...d allows you to cleanly stop all running services The keys have the following functions Exits the current menu When the key is pressed a couple of times the modifications are discarded and the initial state will be displayed Use these keys to switch between the different menus and or characters Pressing this key executes the configured action Starting factory reset 1 Press the Enter key 2 Press th...

Страница 6: ... 625 appliance is designed for a use in racks Please consider the following security hints Important note The appliance is designed for use in rack systems Functional reliability outside of a rack cannot be guaranteed Warnings and precautions The appliance can be operated safely if you observe the following notes and the notes on the appliance itself Rack precautions Ì Ì Make sure that the levelin...

Страница 7: ...k so that airflow required for safe operation is not blocked Ì Ì Mechanical loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Ì Ì Circuit overloading Follow the equipment nameplate ratings to avoid possible circuit overload Ì Ì Reliable grounding Reliable grounding must be maintained at all times To ensure this the rack it...

Страница 8: ...cient airflow and ease in servicing This product is for installation only in a restricted access location dedicated equipment rooms service closets and the like 3 Install the rails to the rack 3 1 Telescope the inner and the outer rail 3 2 Secure the inner rail at the back side of the rack with the fastenings 3 3 Pull the outer rail from the inner rail 3 4 Secure the front of the outer rail to the...

Страница 9: ...working Immediately exchange damaged hard drives Only use hard disks which you purchased directly from Sophos or from a Sophos distribution partner Please remember that any warranty claims are voided for the appliance if a defect has been caused by the use of hard disks which are not suited for the system Exchanging the hard disk 1 Identify the defective hard disk In the event of a hardware defect...

Страница 10: ...er supply system otherwise the complete security appliance will fail Protect yourself from potential burns by wearing protective gloves when exchanging a power supply unit Only use power units which you purchased directly from Sophos or from a Sophos distribution partner Please remember that any warranty claims are not available for the security appliance if a defect has been caused by the use of ...

Страница 11: ... existing network The following SFP GBIC module types may be used Ì Ì N 1000 Base T IEEE 802 3 1 Gbit s via Ethernet cable An Ethernet cable category 5 covers a maximum distance about 100 meters Ì Ì 1000 Base SX IEEE 802 3 1 Gbit s via fiberglass Multi mode fiberglass cables MMF can cover a distance of 200 m to 550 m Ì Ì 1000 Base LX IEEE 802 3 1 Gbit s via fiberglass Here exclusively singlemode f...

Страница 12: ...he module carefully from the port Depending on when you purchased your SFP GBIC module it may have any of three different release mechanisms a plastic tab on the bottom of the mini GBIC a wire bail or a plastic collar around the mini GBIC Please read the operation manual to the SFP GBIC module 10 Serial console You can connect a serial console to the COM port of the Astaro Security Gateway hardwar...

Отзывы: