6
Self-diagnosis Code
Symptom/State
Correction
Repaired
by:
Block
Function
Detailed
Code
E
61
30
Reset position detection error on the
stepper iris initializing
Turn the power on to open lens barrier. Disconnect the
battery or power cord, and then connect again. And
confirm that the iris blades in lens are working.
If iris blades do not work, check the iris motor drive
circuit in lens drive block. If iris blades work normally,
confirm that they are closing completely and confirm
following items.
•
Case of the iris blades do not close normally. Replace
the lens block.
•
Case of “E: 61: 30” is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
•
Case of LCD is not displayed normally, check that
connection between imager board and main board.
•
Case of LCD is displayed normally, replace the lens
block.
E
62
00
Steadyshot does not work well.
(With PITCH angular velocity
sensor output stopped)
The peripheral circuit of the PITCH angular velocity
sensor may be faulty.
Replace the board that contains this peripheral circuit.
E
62
01
Steadyshot does not work well.
(With YAW angular velocity sensor
output stopped)
The peripheral circuit of the YAW angular velocity
sensor may be faulty.
Replace the board that contains this peripheral circuit.
E
62
02
Abnormality of IC for steadyshot.
Check signal line connections from CPU through
steadyshot IC to PITCH/YAW drive.
When there is no problem with the connections, replace
the board that contains this peripheral circuit.
E
62
04
Image vibration correction during
steadyshot does not work.
The image vibration angular velocity sensor peripheral
circuit may be faulty.
Replace the board that contains this peripheral circuit.
E
62
10
Shift lens initializing failure
Replacement of lens block. *1
If an error occurs again, steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
E
62
11
Shift lens overheating (PITCH)
Check signal line connections from CPU through
steadyshot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
62
12
Shift lens overheating (YAW)
Check signal line connections from CPU through
steadyshot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
62
20
Abnormality of thermistor
Check signal line connections from CPU through
steadyshot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
91
01 *2
Abnormality when flash is being
charged
Checking of flash unit or replacement of flash unit.
E
92
00
Battery/Dry cell distinction defect
Turn power off and turn power on again.
E
94
00 *2
Fault of writing or erasing the
internal memory
Turn power off and turn power on again.
E
94
02
BGM data error
The CPU may be faulty.
Replace the board that contains this peripheral circuit.
E
95
00 *2
GPS hardware error
Check the signal line connection for GPS.
When there is no problem with the connections, replace
the board that contains this peripheral circuit.
E
95
01
Acceleration sensor hardware error
Turn power off and turn power on again.
When this error is not cleared, the peripheral circuit of
the acceleration sensor may be faulty.
Replace the board that contains this peripheral circuit.
E
95
02 *2
Electronic compass hardware error
(GPS hardware error)
The peripheral circuit of the electronic compass may be
faulty.
Replace the board that contains this peripheral circuit.
*1: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items. After the adjustment,
make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*2: Function of this code is not provided in this unit.
Sony CONFIDENTIAL
For Authorized Servicer
SYS SET
2020/05/28 23:46:49 (GMT+09:00)