5-11. VIDEO ADJUSTMENT
Conditions:
TEST MODE (See 8 page)
10-step gray scale signal input
NTSC mode
5-11-1. Brightness Signal Contrast Level (Y GAIN)
Adjustment Method:
1) Select Y Gain from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level A stands at the specified value
using the
[INPUT/+]
and
[DIMMER/--]
buttons.
Specified value:
3.8
±
0.1 V
Adjustment location:
Main board
5-11-2. Black Limiter Level Adjustment
Adjustment Method:
1) Select Black Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level B stands at the specified value
using the
[INPUT/+]
and
[DIMMER/--]
buttons.
Specified value:
1.05
±
0.15 V
Adjustment location:
Main board
5-11-3. White Limiter Level Adjustment
Adjustment Method:
1) Select White Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level C stands at the specified value
using the
[INPUT/+]
and
[DIMMER/--]
buttons.
Specified value:
3.95
±
0.15 V
Adjustment location:
Main board
5-8. NTSC SUBCARRIER CHECK
1. Subcarrier Check
Checking Method:
1) Press the
[POWER]
button and enter the NTSC mode using the
[INPUT/+]
and
[DIMMER/--]
buttons.
2) Connect frequency counter between TP503 (+) and TP502 (–).
3) Verify that the reading on the counter is at 3.579545 MHz
±
100
Hz.
Checking location:
Main board
5-9. PAL SUBCARRIER CHECK
1. Subcarrier Check
Checking Method:
1) Press the
[POWER]
button and enter the PAL mode using the
[INPUT/+]
and
[DIMMER/--]
buttons.
2) Connect frequency counter between TP503 (+) and TP502 (–).
3) Verify that the reading on the counter is at 4.433619 MHz
±
100
Hz.
Checking location:
Main board
5-10. V COM VOLTAGE/POSITION ADJUSTMENT
Condition:
TEST MODE (See 8 page)
1. Voltage Setup Adjustment
Adjustment method:
1) Select Com Gain from the FOR FACTORY MODE.
2) Connect oscilloscope between TP725 (+) and TP654 (–).
3) Adjust so that the p-p value A of the waveform stands at the
specified value using the
[INPUT/+]
and
[DIMMER/--]
buttons.
4) Adjust so that the level B on the negative side stands at the
specified value using RV652.
5) Verify that the level C on the positive side stands at the specified
value.
Specified value A:
6.0
±
0.1 Vp-p
Specified value B:
–1.4
±
0.1 V
Specified value C:
4.6
±
0.1 V
Adjusting location:
Main board
C
B
0V
A
A
0V
B
0V
C
0V