– 8 –
SECTION 4
DIAGRAMS
4-1. IC PIN DESCRIPTIONS
• IC502 CXD2710R (DIGITAL SIGNAL PROCESSOR)
Pin No.
Pin Name
I/O
Pin Description
1
AMPIN
I
Loop filter amplifier input for the PLL.
2
AMPOUT
O
Loop filter amplifier output for the PLL.
3
VDD
—
Digital power supply pin (+5 V)
4
VSS
—
Ground
5
AVSS1
—
Ground (for PLL)
6
VCOC
I
VCO control input
7
AVDD1
—
Power supply pin (for PLL) (+5 V)
8
VCOOUT
O
VCO output for the PLL. Not used. (open)
9
MCK1
I
Master clock (768Fs) input
10
MCK2
I
Master clock (384Fs) input
11
MCKOUT
O
Master clock (384Fs) output. Not used. (open)
12
MCKSEL
I
Input for clock signal setting internal VCO or MCK1 (pin
9
).
Internal VCO used: “L”, MCK1 (pin
9
) used: “H” (Fixed at “L”.)
13
XMUTE
I
Output mute signal input of the serial interface. (“L”: mute ON) (Fixed at “H”.)
14
DIN
I
Program data serial input
15
VSS
—
Ground
16
SCK
I
Program data shift clock signal input
17
XLD
I
Program data load input
18
DOUT
O
Internal data serial output to the system control (IC702).
19
BUSY
O
Busy signal at serial data transfer output to the system control (IC702).
20
XCLR
I
Reset signal input from the system control (IC702). “L”: reset
21 – 27
TEST
I
Test pin (Normally connect to ground.)
28
VDD
—
Digital power supply pin (+5 V)
29
VSS
—
Ground
30 – 38
TEST
I
Test pin (Normally connect to ground.)
39
TEST
—
Test pin (Normally open.)
40
VSS
—
Ground
41 – 52
TEST
—
Test pin (Normally open.)
53
VDD
—
Digital power supply pin (+5 V)
54
VSS
—
Ground
55 – 64
TEST
—
Test pin (Normally open.)
65
VSS
—
Ground
66 – 74
TEST
—
Test pin (Normally open.)
75
EBDIR
I
Test pin (Normally connect to ground.)
76
UBDIR
I
Test pin (Normally connect to ground.)
77
TEST0
I
Test pin (Normally connect to ground.)
78
VDD
—
Digital power supply pin (+5 V)
79
VSS
—
Ground
80
TEST1
I
Test pin (Normally connect to ground.)
81
DTEST0
I
Test pin (Normally connect to ground.)
82
DTEST1
I
Test pin (Normally connect to ground.)
83
AVDD2
—
Power supply pin (for D-RAM) (+5 V)
84
AVSS2
—
Ground (for D-RAM)
85
AVDD3
—
Power supply pin (for D-RAM) (+5 V)
86
AVSS3
—
Ground (for D-RAM)
87
S3OUT
O
Serial data output of 1 sampling, 2 channel.
88
S2OUT
O
Serial data output of 1 sampling, 2 channel.
89
S1OUT
O
Serial data output of 1 sampling, 2 channel.
90
VSS
—
Ground
91
S3DI
I
Serial data input of 1 sampling, 2 channel.
92
S2DI
I
Serial data input of 1 sampling, 2 channel.
Содержание XDP-4000X Operating Instructions (primary manual)
Страница 4: ... 4 This section is extracted from instruction manual SECTION 2 GENERAL ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 19: ...XDP 4000X 23 24 Page 37 Page 35 Page 38 Page 35 Page 35 ...