Alarms
An alarm (warning message) appears in the status display
area when an operation is attempted which is inappropriate
for the settings on this unit or the state of a media. Both the
alarm message and the action to take to resolve the
problem appear on the video monitor screen.
When an alarm is displayed, remove the alarm cause by
following the action to take. If the alarm display does not
disappear, contact your Sony representative.
When the unit is powered on
When a memory card is inserted
Example alarm in status display area
Example alarm in video monitor screen
Alarm message in status
display area
Alarm message in video monitor screen Description/action
ILL. SETUP!
INVALID SETTINGS SELECTED IN
SETUP MENU.
SET ITEMS IN THE SETUP MENU TO
THE APPROPRIATE VALUES.
CONTACT SERVICE IF THIS ALARM
APPEARS AGAIN AFTER ABOVE
PROCEDURE.
Reset the settings in the setup menu
.
If the same message appears after you reset the
settings, contact your Sony representative.
Exchg batt!
BATTERY NEEDS REPLACING.
PLEASE CONTACT SERVICE.
The battery of the internal clock is exhausted.
Contact your Sony service or sales representative.
Run Software Update
Program.
RUN SOFTWARE UPDATE PROGRAM.
The software update is not properly performed.
Update the software version again. If the same
message appears after you update the software
version, contact your Sony representative.
Alarm message in status
display area
Alarm message in video monitor screen Description/action
Unknown Media(A/B)
UNKNOWN MEDIA(A/B).
PLEASE CHANGE.
The inserted memory card has been partitioned, or it
contains more clips that the maximum that can be
handled by this unit.
Insert a memory card that has not been partitioned,
or one that contains fewer than the maximum number
of clips.
Memory (A/B) needs
Restoring.
MEDIA ERROR.
MEDIA(A/B) NEEDS TO BE RESTORED.
A memory card must be restored because an error
has occurred in the card.
Restore the card or format it.