![background image](http://html.mh-extra.com/html/sony/xdca-55/xdca-55_operating-instructions-manual_390557009.webp)
9
Names and Functions of Parts
a
INTERCOM MIC switch
Controls the headset microphone connected
to the INTERCOM connector, turning it on
or off as required.
ON:
Turns the headset microphone on.
OFF:
Turns the headset microphone off.
PTT:
Turns the headset microphone on for
as long as the switch is held in this
position.
b
TALLY lamp (green)
When the TALLY switch is on, lights in
green when a green tally signal is input to
an XDCU-50 connected to the adaptor.
c
TALLY lamp (red)
When the TALLY switch is on, lights in red
when a red tally signal is input to an
XDCU-50 connected to the adaptor, and
when a call signal is received, for example
because a CALL button was pressed on
another device.
This lamp does not light when the adaptor’s
CALL button is pressed.
d
TALLY switch
Enables (on) or disables (off) the TALLY
lamps (red and green).
However, tally signals assigned to pins 14
and 15 of the AUX connector are not
affected by the setting of this switch.
ON:
Lights the TALLY lamps (red and
green) according to tally signals and
the state of the CALL button.
OFF:
Does not light the TALLY lamps (red
and green).
e
Belt bracket screw holes
These are screw holes (2) for M3 screws to
secure a belt bracket.
f
CALL button
Calls the operator of a XDCU-50 or remote
control unit.
When this button is pressed, the TALLY or
CALL lamps on the camcorder, the XDCU-
50, and the remote control unit light. On the
other hand, the TALLY lamp on this
adaptor does not light.
Control over tally lamps varies depending
on the devices used in the system
(camcorder, XDCU-50, remote control
unit).
For details, refer to the instruction manuals of the
other devices.
g
RET (return) button
Switches the video in the viewfinder to
return video.
When the MONI. SEL switch is set to
CAM/RET, you can also switch the output
signal from the MONITOR OUT(SDI)
connector to return video.
h
MONI. SEL (monitor select) switch
Selects the output from the MONITOR
OUT(SDI) connector.
RET:
Always outputs return video signals.
CAM/RET:
Outputs return video as long
as the RET button is pressed, and
outputs camcorder video signal when
the RET button is not pressed.
i
CEU OUT (camera extension unit
output) connector
Connect to the CA IN connector of the
XDCU-50 with a BNC cable (5C-FB).
j
CEU IN (camera extension unit
input) connector
Connect to the CA OUT connector of the
XDCU-50 with a BNC cable (5C-FB).
k
MONITOR OUT(SDI) connector
Outputs HD SDI signals, either return video
signals from the XDCU-50 video signals
from the camcorder.
Note
Note
Содержание XDCA-55