20
Trigger delay
The camera can delay the trigger signal.
Trigger counter
This counts the number of accepted triggers. Triggers that have been removed because they exceed the trigger range
limit and triggers input with invalid timing are not counted. The trigger counter returns to 0 when the upper limit
(2147483647) is reached. The trigger counter can be reset to 0 by issuing TriggerCounterReset.
Trigger range limit
Only signals in the set trigger width can be accepted as a trigger signal. This functions as a noise filter, which removes
chattering or disturbance noise in the trigger signal line. When a trigger signal is input, exposure is started with a time
lag set by the trigger range set value. No image is output outside the trigger signal width set range.
Trigger range operation example
ExposureTime=300, TriggerAcceptanceRangeLowerLimit=100 in the figure.
Feature
Parameter
Setting
TriggerDelay
0 to 4000000 Trigger delay [µs]
Feature
TriggerCounter
TriggerCounterReset
Feature
Parameter
Setting
TriggerAcceptanceRangeEnable
False (0) Trigger
range
off
True (1)
Trigger range on
TriggerAcceptanceRangeLowerLimit
1 to 2000000
Trigger range lower limit [µs]
Trigger signal
Sensor output
Exposure
100μ
s
Trigger signal
Sensor output
Exposure