![Sony XCHR58 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/sony/xchr58/xchr58_technical-manual_418387019.webp)
19
Mode Settings
XC-HR58
Binning OFF mode
Binning ON mode
• The shaded parts of the tables are items that you set or input yourself.
• The table is an example in external trigger shutter mode 1 where the
trigger pulse width is 100
µ
s, and the time from the trigger rising edge to
external VD falling edge is about 1 H (32.0
µ
s). In this case, about 2 lines
at the end of the effective image segment are affected by trigger input.
• The number of effective lines with high-rate scan set to ON is determined
by the formula shown below.
X = T – Tb – 2
where Tw: External VD width [line]
Tb: BLKG interval [line]...45 [line] (constant)
T: Trigger interval [line]
2: Ineffective interval [H] caused by trigger input
Note that there is no difference in the formula of effective lines between
Binning ON and Binning OFF.
Effective lines
X [line]
578 (18.50 ms)
256 (8.19 ms)
160 (5.12 ms)
88 (2.82 ms)
Trigger interval
T [line]
625 (20.00 ms)
303 (9.70 ms)
207 (6.62 ms)
135 (4.32 ms)
External VD width
Tw [line]
High-rate scan OFF
14
18
21
BLKG interval
Tb [line]
45 (1.44 ms)
45 (1.44 ms)
45 (1.44 ms)
45 (1.44 ms)
Frame rate
[frame/s]
50
100
150
200
Trigger interval
T [line]
313 (10.02 ms)
148 (4.74 ms)
100 (3.20 ms)
External VD width
Tw [line]
High-rate scan OFF
16
20
Effective lines
X [line]
266 (8.51 ms)
101 (3.23 ms)
53 (1.70 ms)
BLKG interval
Tb [line]
45 (1.44 ms)
45 (1.44 ms)
45 (1.44 ms)
Frame rate
[frame/s]
99.8
200
300