23
Control
XCD-SX910CR/X710CR
XCD-SX910UV
XCD-SX910/X710
Before sending a command, check the predetermined
variable range and check whether the feature supports
AUTO mode.
Note that variable ranges for Pan/Tilt differ
*
1)
According to the IEEE 1394 specifications, the most significant bit is shown as 0.
*
2)
These features comply with IIDC v.1.31.
considerably depending on the video mode. After
switching video mode, check the variable range of the
new video mode.
Address
Data
Bit*
1)
F0F00500h
8905A073h
0
This feature exists.
(Brightness)
4
The value can be read out.
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 63
F0F00504h
8905A073h
0
This feature exists.
(AutoExposure)
4
The value can be read out.
7
Manual setting can be selected.
8-19
Min. 90
20-31
Max. 115
F0F0050Ch
CB003424h
0
This feature exists.
(White Balance)
4
The value can be read out.
(XCD-SX910CR/X710CR only)
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 127
F0F00510h
8B1803FFh
0
This feature exists.
(Hue)
4
The value can be read out.
(XCD-SX910CR/X710CR only)
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 63
F0F0051Ch
CB003424h
0
This feature exists.
(Shutter)
1
Absolute value control possible
4
The value can be read out.
6
Auto setting can be selected.
7
Manual setting can be selected.
8-19
Min. 3
20-31
Max. 1150
F0F00520h
8B1803FFh
0
This feature exists.
(Gain)
4
The value can be read out.
6
Auto setting can be selected.
7
Manual setting can be selected.
8-19
Min. 384
20-31
Max. 1023
F0F00530h
8C81C000h
0
This feature exists.
4
The value can be read out.
5
Feature can be switched between ON and OFF.
8
Trigger Source0 exists.*
2)
15
Software Trigger Mode exists.*
2)
16
Trigger Mode0 exists.
17
Trigger Mode1 exists.
F0F00584h
89******
0
This feature exists.
(Pan)
4
The value can be read out.
F0F00584h
7
Manual setting can be selected.
(Tilt)
8-19
Min. (Depends on the video mode.)
20-31
Max. (Depends on the video mode.)
F0F0058Ch
8C81C000h
0
This feature exists.
(Optical Filter)
4
The value can be read out.
(XCD-SX910CR/X710CR only)
7
Manual setting can be selected.
8-19
Min. 0
20-31
Max. 3