9
XC-E series
A
B
T
A: 4 to 5.0 V
B: 0 to 1.0 V
T: 2
µ
s to 1/4 s
ELECTRONIC SHUTTER
•
Using trigger pulse width
•
Set DIP switches 1 to 4 on the rear panel to 0.
•
An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2
µ
sec to 250
msec.
Exposure time = Trigger pulse width + 97
µ
sec (EIA)
120
µ
sec (CCIR)
Specifications of trigger pulse
T: 2
µ
s to 1/4 s, 100
µ
s to 1/4 s when setting the shutter speed using DIP switch
*
Input impedance: 10 kW or more
*
The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
1
0
0
Switch
Mode 1
(Non-reset mode)
Mode 2
(Reset mode)
1
2
3
4
5
6
7
8
9
0
Frame: 0 / Field: 1
: 1. lt is recommended to set DIP switch 5 for field selection.
(The field selection is about two times in sensitivity as high as the frame selection.)
2. After a trigger pulse is input, a new trigger pulse must not be input before the video
signal obtained by the trigger pulse has been output.
1: ON
0: OFF
Note