NOTE THE MAIN BOARD OR SYSTEM CONTROLLER
(IC502) REPLACING
When the complete MAIN board or system controller (IC502) is
replaced, the destination setting is necessary.
1. Preparing the Destination Setting
Be sure to solder the SL501 on the MAIN board before doing the
destination setting.
– MAIN Board (Component Side) –
IC502
SL501
2. Destination Setting
Set destination according to the procedure below.
2-1. Setting the Destination Code
1. In the state of source off (Home screen is displayed), enter the
test mode by pressing the buttons in order of the [4]
t
[5]
t
[6] on the remote commander (press only the [6] button for
two seconds).
2. The following screen is displayed and the destination setting
mode becomes effective.
(Displayed characters/values in the following
fi
gure are ex-
ample)
Note:
Refer to following “2-2. Entering the Destination Code” for opera-
tion method.
<DESTINATION SETTING>
0
0 0 0 0 2
EUR 000000
MECHA(EUR)
000006
UC 000001
FT(JPN)
000007
E17(P3E) 000002
BR(N4E) 000008
E(N4E) 000003
EA
00000A
RU2(P5EUR) 000004 EJ(EUR)
00000B
3. The resetting operation is executed by pressing the [SOURCE/
OFF] button for 1 second after the setting ends, and the unit
returns to the normal condition.
2-2. Entering the Destination Code
Note:
Input of the destination code cannot be performed by the keys of
main unit. Be sure to input the destination code by remote com-
mander.
• Method of operation by remote commander
1. Press the [ ] or [ ] button, and select the alphanumeric char-
acter of “0 to F”.
2. The digit advances by pressing the [
] button.
The digit returns by pressing the [
] button.
3. The setting is completed by pressing the [ENTER] button, and
the initialization operation is done.
2-3. Destination Code
Model
Destination
Destination code
XAV-701BT
E (NTSC) model
000003
XAV-701BT/741
E (PAL) model
000002
XAV-701BT
South African model
00000B
XAV-701BT/741
Russian model
000004
3. Con
fi
rmation After Destination Setting
Execute the following operation after completing the destination
setting, and con
fi
rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (Home screen is displayed), enter the
test mode by pressing the buttons in order of the [4]
t
[5]
t
[0] on the remote commander (press only the [0] button for two
seconds).
2. The following screen is displayed and con
fi
rm that item of the
destination has been rewritten correctly.
(Displayed characters/values in the following
fi
gure are ex-
ample)
<TEST MODE>
AVC Ext
NAVI
Temperature : 0xf9
Bluetooth
1. Audio FACTORY MODE
2. Audio DEBUG MODE
4. Visual FACTORY MODE
5. ENGINEER MODE
6. DESTINATION MODE
8. MECHA MODE
9. NAVI/RGB-OUT MODE
Master: SR04
Mecha:
BT Module: 3010
Display: SA08
Navigation:
Destination: E3P
Region: 0
AP : SR06
3. The resetting operation is executed by pressing the [SOURCE/
OFF] button for 1 second after the con
fi
rming ends, and the
unit returns to the normal condition.
4. Processing After the Destination Setting
Be sure to unsolder the SL501 on the MAIN board after doing the
destination setting.