XAV-62BT/622/E62BT/E622
25
SECTION 4
ELECTRICAL ADJUSTMENTS
MONITOR SECTION
If any of the following parts was replaced, execute the “Flicker
Adjustment” as mentioned below.
• Complete MAIN board
• MAIN board: IC402
• Liquid crystal display panel (LCD1401)
• Complete DISP board
1. SETTINGS
1-1. Tools and measuring devices for adjustment
Tools and measuring devices
Item used
PC
(The one with serial port. The USB-
RS232C conversion is available.)
Flicker adjustment
Communication software
(Hyper Terminal etc.)
Serial cable for RS232C
(Cross cable)
RS232-JIG OVERALL ASSY
(Part No. A-1777-380-A)
CONNECTOR CORD (5P)
(Part No. 9-885-156-24)
RS232-JIG OVERALL ASSY
CONNECTOR CORD (5P)
Replacement of the cable
You need to replace the cable, because RS232-JIG OVERLL
ASSY can not be used as is.
RS232-JIG OVERALL ASSY
RS232-JIG OVERALL ASSY
1
Remove the cable
2
Replace with
CONNECTOR CORD (5P)
1-2. Serial port setting
Please setting it as follows.