KLV-23HR2 (UC) 2-2
8. Check that the detection value of “PW_INPUT_CB” is within
the standard of the following column.
9. Input red full field with burst.
10. Send “READ_PW_INPUT_CR” command from ECS.
11. Check that the detection value of “PW_INPUT_CR” is within
the standard of the following column.
2-1-6. Y signal AD calibration of DVI input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 4 input .
4. Send “READ_PW_INPUT_Y” command from ECS.
5. Check thgat the detection value of “PW_INPUT_Y” is within
the standard of the following column.
6. Input 100 IRE white full field with burst.
7. Send “ADJUST_Y_LEVEL_DVI” command from ECS.
The Y_LEVEL_CCP2_04 registration of the DVI_D1 range
is adjusted automatic by this command.
Adjustment value also is copied in the DVI_D2, DVI_D3
and DVI_D4 range.
8. Check that the detection value of “PW_INPUT_Y” is within
the standard of the following column.
2-1-7. C signal AD calibration of DVI
input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 3 input .
4. Send “READ_PW_INPUT_CB” command from ECS.
2-1-4. Y signal AD calibration of COMPONENT
input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 3 input .
4. Send “READ_PW_INPUT_Y” command from ECS.
5. Check thgat the detection value of “PW_INPUT_Y” is within
the standard of the following column.
6. Input 100 IRE white full field with burst.
7. Send “ADJUST_Y_LEVEL_D1” command from ECS.
The Y_LEVEL_CCP2_04 registration of the D1 range is ad-
justed automatic by this command.
Adjustment value also is copied in the D2, D3 and D4 range.
8. Check that the detection value of “PW_INPUT_Y” is within
the standard of the following column.
2-1-5. C signal AD calibration of COMPONENT
input.
1. Check “CP_CTRL” = 0
2. Set data as follows.
3. Input 0 IRE black full field with burst in video 3 input .
4. Send “READ_PW_INPUT_CB” command from ECS.
5. Check thgat the detection value of “PW_INPUT_CB” is
within the standard of the following column.
6. Input blue full field with burst.
7. Send “ADJUST_C_LEVEL_D1” command from ECS.
The C_LEVEL_CCP2_05 registration of the D1 range is ad-
justed automatic by this command.
The value that increased and redused offset data is copied in
the D2, D3 and D4 range.
<Setting data>
COLOR
25
DYNA_PICT
0 (OFF)
DC_TRAN
0 (OFF)
<Setting data>
COLOR
25
DYNA_PICT
0 (OFF)
DC_TRAN
0 (OFF)
<Video(composit) input detection value average on 0
IRE black full field>
Item
Standard
PW_INPUT_CB
128
±
5
<Video 3 input standard value on blue full field>
Item
Standard
PW_INPUT_CR
230
±
3
<Video 3 input detection value average on 100 IRE white
full field>
Item
Standard
PW_INPUT_Y
195
±
2
<Video 3 input detection value average on 0 IRE black
full field>
Item
Standard
PW_INPUT_Y
11
±
3
<Video 3 input standard value on blue full field>
Item
Standard
PW_INPUT_CB
230
±
2
<Setting data>
COLOR
25
DYNA_PICT
0 (OFF)
DC_TRAN
0 (OFF)
<Video 4 input detection value average on 0 IRE black
full field>
Item
Standard
PW_INPUT_Y
11
±
3
<Video 4 input detection value average on 100 IRE white
full field>
Item
Standard
PW_INPUT_Y
195
±
2
<Setting data>
COLOR
25
DYNA_PICT
0 (OFF)
DC_TRAN
0 (OFF)