14
NW-HD1
5-3-4. LCD display check
LCD display is checked.
Checking method:
1. Enter the test mode.
2. Press the
,
key to display major item, and press the
M m
key to select the “OTHERS”.
3. Press the
,
key to display minor item, and press the
M m
key to select the “LCD 1”.
4. Press the
Bx
key, LCD all segments of main unit and remote
commander are turned on.
5. Press the
[SET UP]
key to display minor item, and press the
M
m
key to select the “LCD 2”.
6. Press the
Bx
key, LCD all segments of main unit and remote
commander are turned off.
7. Press the
[SET UP]
key to display minor item, and press the
M
m
key to select the “LCD 3”.
8. Press the
Bx
key, monochrome lattice is displayed on the LCD
of main unit.
9. Press the
[SET UP]
key to display minor item, and press the
M
m
key to select the “LCD 4”.
10. Press the
Bx
key, monochrome lattice (reverse version of step
8) is displayed on the LCD of main unit.
11. Press the
[SET UP]
key, return to minor item selection screen.
5-3-5. G-sensor adjustment
X/Y/Z-axis direction is adjusted.
Adjustment method:
1. Enter the test mode.
2. Press the
,
key to display major item, and press the
M m
key to select the “OTHERS”.
3. Press the
,
key to display minor item, and press the
M m
keyÍ to select the “G CLB”.
4. Press the
Bx
key, “+X” is displayed. Main unit is fixed so that
1
of fig.1 may become downward and press the
Bx
key.
OTHERS
LCD display
LCD 1
LCD display
LCD 2
LCD display
LCD 3
LCD display
LCD 4
LCD display
5. “–X” is displayed. Main unit is fixed so that
2
of fig.1 may
become downward and press the
Bx
key.
6. “+Y” is displayed. Main unit is fixed so that
3
of fig.1 may
become downward and press the
Bx
key.
7. “–Y” is displayed. Main unit is fixed so that
4
of fig.1 may
become downward and press the
Bx
key.
8. “+Z” is displayed. Main unit is fixed so that
5
of fig.1 may
become downward and press the
Bx
key.
9. “–Z” is displayed. Main unit is fixed so that
6
of fig.1 may
become downward and press the
Bx
key.
10. “CALIB” is displayed. Press the
Bx
key, G-sensor is adjusted.
Then “FIN”, “DAT NG” or “SEN NG” is displayed automatically.
FIN
: adjusted normally.
DAT NG : The data for performing a calibration is faulty.
SEN NG : The value acquired from the G-sensor is faulty.
11. Press the
[SET UP]
key, return to minor item selection screen.
CALIB
LCD display
FIN
r
OTHERS
LCD display
G CLB
LCD display
+X
LCD display
-X
LCD display
+Y
LCD display
-Y
LCD display
+Z
LCD display
-Z
LCD display
Fig.1 Axis direction of G-sensor adjustment
4
2
5
3
1
6
Ver 1.1
Содержание Walkman NW-HD1
Страница 67: ...19 NW HD1 MEMO ...