![Sony Walkman MZ-NF810CK Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/sony/walkman-mz-nf810ck/walkman-mz-nf810ck_service-manual_412226021.webp)
21
MZ-NF810/NF810CK
• Adjustment Method of CHGV_LOW
(item number: 755)
Note:
Remove the rechargeable battery.
1. Connect a digital voltmeter to the BATT+ on the MAIN board,
and adjust
[VOL +]
key (voltage up) or
[VOL --]
key (voltage
down) so that the voltage becomes 1.35 ± 0.01V.
2. Press the
X
key on the set or the key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 22)
• Adjustment Method of CHGV_HIGH
(item number: 756)
Note:
Remove the rechargeable battery.
1. Connect a digital voltmeter to the BATT + on the MAIN board,
and adjust
[VOL +]
key (voltage up) or
[VOL --]
key (voltage
down) so that the voltage becomes 1.80 ± 0.015V.
2. Press the
X
key on the set or the key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 22)
• Adjustment Method of CHGI_LOW (Charge Current)
(item number: 757)
Note:
Remove the rechargeable battery.
Connect the resistor (47 ) (0.5%) between terminals of
BATT + and BATT –.
1. Connect a digital voltmeter to the BATT + on the MAIN board,
and adjust
[VOL +]
key (voltage up) or
[VOL --]
key (voltage
down) so that the voltage becomes 1.41 ± 0.015V.
2. Press the
X
key on the set or the key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 22)
• Adjustment Method of CHGI_HIGH (Charge Current)
(item number: 758)
Note:
Remove the rechargeable battery.
Connect the resistor (10 ) (0.5%) between terminals of
BATT + and BATT –.
1. Connect a digital voltmeter to the BATT + on the MAIN board,
and adjust
[VOL +]
key (voltage up) or
[VOL --]
key (voltage
down) so that the voltage becomes 1.40 ± 0.015V.
2. Press the
X
key on the set or the key on the remote
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
(see page 22)
digital
voltmeter
BATT + (W902)
BATT – (GND)
MAIN board
10
Ω
(0.5%)
756
C h g V H * *
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT +(W902)
BATT – (GND)
MAIN board
757
C I L * *
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT + (W902)
BATT – (GND)
MAIN board
47
Ω
(0.5%)
758
C I H * *
**
: Adjusted value
Remote commander LCD display
755
C h g V L * *
**
: Adjusted value
Remote commander LCD display
digital
voltmeter
BATT +(W902)
BATT – (GND)
MAIN board
Содержание Walkman MZ-NF810CK
Страница 36: ...36 MZ NF810 NF810CK MEMO ...