background image

8

VPL-HW15

Table 2-10 Infrared Remote Command Code for 20 bit PRJECTOR-EE

CATEGORY

Code

Name

20 bit 
PROJECTOR-EE

O

6E

OPTIONS

O

6F

EXIT

O

70

SYNC MENU ON/OFF

O

71

PLAY

O

72

STOP

O

73

PAUSE

O

74

FAST REWIND

O

75

FAST FORWARD

O

76

PREVIOUS

O

77

NEXT

2-2. Reply

<Table 3>

Item Number

Data

Item

Data

Upper byte

Lower byte

ACK

COMPLETE

00h

00h

NAK

UNDEFINED COMMAND

01h

01h

SIZE ERROR

04h

SELECT ERROR

05h

RANGE OVER

06h

NOT APPLICABLE

0Ah

CHECK SUM ERROR

F0h

10h

FRAMING ERROR

20h

PARITY ERROR

30h

OVER RUN ERROR

40h

OTHER COMM ERROR

50h

Error description

Check Sum Error

A check sum error occurred.

Framing Error

A framing error occurred.

Parity Error

A parity error occurred.

Over Run Error

An overrun error occurred.

Other Comm Error

Another error occurred.

Содержание VPL VPL-HW15

Страница 1: ...VIDEO PROJECTOR VPL HW15 PROTOCOL MANUAL 1st Edition ...

Страница 2: ... dürfen nur von qualifiziertem Fachpersonal ausgeführt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux p...

Страница 3: ...mmands 2 1 Sub Commands 2 2 1 1 ITEM List 2 2 1 2 Infrared Remote Command Code 6 2 2 Reply 8 3 RS 232C 3 1 Connection 9 3 2 Communication Specifications 9 3 3 Communication Procedure 10 3 4 Command Block Format 11 3 4 1 Simplified Command 11 3 5 Packet Examples 12 3 5 1 Change Wide Mode to Zoom 12 3 6 AMX Device Discovery 12 ...

Страница 4: ......

Страница 5: ... RS 232C 1 2 Glossary of Terms Table 1 1 Glossary of Terms Terms Abbreviated Description CONTROLLER _ Command initiator such as PCs PROJECTOR _ Front projector 1 3 Protocol Stack Structure The protocol stack structure diagram is shown below Though the stack is drawn for RS 232C the follow ing portions are common Table 1 2 Common Portions in Protocol Stack Layer Name Description Sub Command Value i...

Страница 6: ...Upper byte Lower byte Picture Mode 00h 02h Dynamic 0000h Set Get Standard 0001h Cinema 0002h User1 0003h User2 0004h User3 0005h Contrast 00h 10h 0000h to 0064h 0 to 100 Brightness 00h 11h 0000h to 0064h 0 to 100 Color 00h 12h 0000h to 0064h 0 to 100 Hue 00h 13h 0000h to 0064h 0 to 100 Sharpness 00h 14h 0000h to 0064h 0 to 100 Color Temp 00h 17h High 0000h Mid 0001h Low 0002h Custom1 0003h Custom2...

Страница 7: ...h 26h Off 0000h Low 0001h Middle 0002h High 0003h Mosquito NR 00h 27h Off 0000h Low 0001h Middle 0002h High 0003h Color Space 00h 3Bh Normal 0000h Wide 0001h USER GAIN RED 00h 50h FFE2h to 001Eh _30 to 30 USER GAIN GREEN 00h 51h FFE2h to 001Eh _30 to 30 USER GAIN BLUE 00h 52h FFE2h to 001Eh _30 to 30 USER BIAS RED 00h 53h FFE2h to 001Eh _30 to 30 USER BIAS GREEN 00h 54h FFE2h to 001Eh _30 to 30 US...

Страница 8: ...oom 0002h Zoom 0003h Full1 0007h Full2 0008h Over Scan 00h 23h Off 0000h On 0001h Screen Area 00h 24h Full 0000h Through 0001h Table 2 3 ITEM List For Setup Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Input 00h 01h Video 0000h Set Get S Video 0001h Input A 0002h Component 0003h HDMI1 0004h HDMI2 0005h Picture Muting 00h 30h Off 0000h On 0001h ...

Страница 9: ...e lamp timer indicates 1000H return values are 03h upper byte and E8h lower byte Table 2 5 ITEM List For Infrared Remote Command Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote Command 15 bit category 17h Refer to the section 2 1 2 1 00h 00h Set Only Infrared Remote Command 20 bit category 19h Refer to the section 2 1 2 1 Table 2 6 Tab...

Страница 10: ... HIGH O _ 19 CONTRAST _LOW O _ 1A COLOR HIGH O _ 1B COLOR _LOW O _ 1E BRIGHTNESS BRIGHT O _ 1F BRIGHTNESS _DARK O _ 20 HUE GREENISH O _ 21 HUE _PURPLISH O _ 22 SHARPNESS SHARP O _ 23 SHARPNESS _SOFT _ O 08 RCP _ O 09 ADJUST PICTURE TOGGLE _ O 4B COLOR SPACE TOGGLE _ O 51 PICTURE MODE DYNAMIC _ O 52 PICTURE MODE STANDARD _ O 53 PICTURE MODE CINEMA _ O 54 PICTURE MODE USER1 _ O 55 PICTURE MODE USER2...

Страница 11: ...URE MUTING O _ 25 STATUS ON O _ 26 STATUS OFF O _ 29 MENU O _ 2A VIDEO O _ 2B INPUT A O _ 2C COMPONENT O _ 2E POWER ON 1 O _ 2F POWER OFF O _ 33 CURSOR O _ 34 CURSOR O _ 35 CURSOR O _ 36 CURSOR O _ 57 INPUT SELECT O _ 5A ENTER O _ 5F S VIDEO O _ 6F HDMI 1 O _ 70 HDMI 2 O _ 7B RESET 1 Send the command twice when this unit is in standby state Table 2 9 Infrared Remote Command Code For Installation C...

Страница 12: ...mber Data Item Data Upper byte Lower byte ACK COMPLETE 00h 00h NAK UNDEFINED COMMAND 01h 01h SIZE ERROR 04h SELECT ERROR 05h RANGE OVER 06h NOT APPLICABLE 0Ah CHECK SUM ERROR F0h 10h FRAMING ERROR 20h PARITY ERROR 30h OVER RUN ERROR 40h OTHER COMM ERROR 50h Error description Check Sum Error A check sum error occurred Framing Error A framing error occurred Parity Error A parity error occurred Over ...

Страница 13: ... TxD Transmit Data 4 N C _ 5 GND Signal Ground 6 N C _ 7 N C _ 8 N C _ 9 N C _ 3 2 Communication Specifications Full duplex communication channels Flow control not performed Start stop synchronism system Baud rate 38 4 kbps bits per second The bit configuration is defined as follows 1 START Bit 8 DATA Bits 1 PARITY Bit 1 STOP Bit EVEN Parity Total number of 1 s from D0 to D7 is an even number 8 0 ...

Страница 14: ...be issued by CONTROLLER and PROJECTOR responses to it Fig 3 1 Command Sequence It is prohibited that CONTROLLER send another command before receiving the response to the previous command Since PROJECTOR executes the command before sending the return data CONTROLLER must wait a while before receiving the response The waiting time depends on the commands Approxi mate waiting time is shown below 30 t...

Страница 15: ...tem list in the sections 2 1 1 and 2 1 2 02h Express data to be Reply data Data value described in the item list in the sections 2 1 1 and 2 1 2 3 4 Command Block Format There are 2 types of block format for RS 232C as shown in the Fig 1 1 In this section the block format for Simplified Command and Simplified Variable Length Command are provided 3 4 1 Simplified Command Send The block format for s...

Страница 16: ...the same purpose There is WIDE MODE TOGGLE key on the infrared remote controller By using this key wide mode can be changed Issue the Infrared Remote Command for this key several times to set wide mode Zoom Packet format will make as follows Refer to the Table 2 7 for wide mode toggle START CODE A9h ITEM NUMBER 196Eh WIDE MODE TOGGLE SET GET 00h SET DATA 0000h CHECK SUM 7Fh END CODE 9Ah 3 6 AMX De...

Страница 17: ... formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich die Vervielfältigung jeglicher Teile dieser An...

Страница 18: ...Sony Corporation VPL HW15 J VPL HW15 SY VPL HW15 UC E 9 968 699 01 Printed in Japan 2009 8 22 2009 ...

Отзывы: