1-5
VPL-FX52/FX52L
1-2-6. C Board Removal
1
Three screws
(
+
PSW 3
x
8)
2
C board
CN5601
CN5801
CN5701
CN3010 (board to board)
CN3009 (board to board)
CN5302
CN5307
CN5305
CN5103
CN5306
CN5303
CN5304
1-2-7. Prism Block (G) Assy and Out-polarization Assy Removal
*
To remove the prism block (G) assy and Out-polarization assy, remove the C board beforehand.
!/
Screw
(
+
PSW 3
x
8)
!-
Gch in-polarization panel
![
Bch in-polarization panel
9
Rch in-polarization panel
5
Out-polarizer (R) JSB assy or
Out-polarizer (R) JRB assy
6
Out-polarizer (G) JSB assy or
Out-polarizer (G) JRB assy
7
Out-polarizer (B) assy
Three flexible cables
!=
Screw
(
+
PSW 3
x
8)
8
Screw
(
+
PSW 3
x
8)
3
Screw
(
+
PSW 3
x
8)
1
Four screws
(
+
P 3
x
5)
2
Cover
4
Prism block (G) assy
Note : Use extreme care not to touch the glass
section of prism, LCD, and conductive
section of the flexible cable in particular.
Note on replacing the OUT-POLARIZER ASSY.
There are two combination methods when replacing the OUT-POLARIZER ASSY.
Check which one of the combination methods is to be used when replacing
the OUT-POLARIZER ASSY. (Refer to 4-11)
Содержание VPL-FX52
Страница 1: ...DATA PROJECTOR VPL FX52 VPL FX52L SERVICE MANUAL 1st Edition Revised 1 ...
Страница 7: ...1 1 VPL FX52 FX52L Section 1 Service Information 1 1 Board Layout H NR LAMP POWER GA C B QA QB S GB ...
Страница 34: ......
Страница 128: ...Printed in Japan Sony Corporation 2005 12 16 2005 VPL FX52 VPL FX52L SY E 9 872 768 02 ...