Sony URX-P03D Скачать руководство пользователя страница 15

15

EXT.IN Menu

This menu allows you to configure settings for the 
microphone connected to the unit’s external input 
connector.

Selecting the external microphone type 
(MIC SELECT)

Select which type of microphone is connected to the 
external input connector.

OFF: 

Select this when not using an external microphone.

PLUG-IN PWR:

 Select this when using a plug-in power 

microphone.

MONO BMP +5V:

 Select this when using a Sony 

lavalier microphone.

Adjusting the input level (INPUT LEVEL)

Set the input level to a value between –12 to +12 dB. 
Adjust the value according to the type of microphone that 
is connected.
The factory default setting is 0 dB.

Setting the low-cut filter (LCF)

You can set the low-cut filter to reduce noise caused by 
wind.
You can set the cutoff frequency to OFF/LOW/MID/
HIGH.

OFF:

 No filtering

LOW:

 100 Hz cutoff frequency

MID:

 150 Hz cutoff frequency

HIGH:

 200 Hz cutoff frequency

Switching the phase of the microphone 
(PHASE)

You can switch the phase of a connected microphone to 
output audio in reverse phase.

NORMAL:

 Phase is not reversed. 

INVERT:

 Reverses the internal phase.

Selecting the output connector for audio 
inputs (ASSIGN)

Select the connector from which to output signal inputs.

OUT1: 

Output the audio from the OUTPUT 1 connector. 

If the connected microphone is an LR type, the output will 
be mixed.

OUT1/2 (L/R):

 Output the audio from both the OUTPUT 

1 and OUTPUT 2 connectors. If the connected 
microphone is an LR type, L will be output from the 
OUTPUT 1 connector and R will be output from the 
OUTPUT 2 connector.

OUT2:

 Output the audio from the OUTPUT 2 connector. 

If the connected microphone is an LR type, the output will 
be mixed.

Error Messages

When a problem occurs, one of the following error 
messages may appear on the display.

Message

Meaning

Solution

EEP ERROR

An error has 
occurred in the 
backup memory 
data.

Contact your Sony 
service representative.

PLL ERROR 

An error 
occurred in the 
PLL synthesizer 
circuit.

Restart the unit. If the 
message persists, 
contact your Sony 
service representative.

NO TONE

Audio signal 
output has been 
muted, because 
a tone signal 
different from 
the compander 
mode 
configured on 
the unit was 
received.

Configure the 
appropriate compander 
mode based on the 
transmitters you are 
using 

“Setting the 

Compander Mode” 
(page 10)

When operating in 
conjunction with UWP-D 
series transmitters 
(UTX-B03, UTX-M03, 
etc.), set the unit and the 
transmitters to the same 
compander mode.

Содержание URX-P03D

Страница 1: ...UHF Synthesized Diversity Tuner Operating Instructions URX P03D 4 593 095 11 1 2016 Sony Corporation ...

Страница 2: ...ithin a Group Clear Channel Scan 9 Searching for Active Channels within a Group Active Channel Scan 10 Setting the Compander Mode 10 Using the Infrared Communication Function 11 Adjusting the Monitor Audio Level 12 Menu Displays and Detailed Settings 12 Menu Structure and Hierarchy 12 Basic Menu Operations 13 UTILITY Menu 13 RX tuner 1 2 Menu 14 EXT IN Menu 15 Error Messages 15 Troubleshooting 16 ...

Страница 3: ...on of materials Diversity reception system The unit employs a space diversity system to minimize dropouts true diversity system during one channel operation for higher stability Compatibility with Sony analog wireless microphones The built in DSP enables digital companding for high quality audio transmissions Switching to compander mode allows operation in conjunction with Sony analog wireless mic...

Страница 4: ...l meter Indicates the input signal level B Peak indicator Warns of excessive input by lighting up when the signal is 3 dB below the level at which distortion begins C Group display Displays the name of the receive group that is configured D Channel display Displays the name of the receive channel that is configured Indicator display Status On green Sufficient battery level Flashing green Battery i...

Страница 5: ...ck balanced output Connect one end of the supplied XLR BMP conversion output cable or the stereo mini plug BMP conversion cable here and the other end to the microphone input on a camcorder mixer or amplifier If the microphone input connector on the connected device is a stereo mini jack connect the straight BMP plug to the tuner and the L shaped stereo mini plug to the microphone input connector ...

Страница 6: ... before replacing the batteries 1 Turn the power off 2 Slide the two catches inward as indicated and pull the battery compartment out 3 Insert two new AA batteries into the battery compartment with 3 and polarities in the correct orientation and close the compartment Make sure that the battery compartment is locked securely Battery level indicator When tuner 1 or tuner 2 is turned on the unit s re...

Страница 7: ...g power using a USB output type AC adapter or portable power supply use a unit that satisfies the following conditions Output connector USB micro B type Rated voltage 5 V Output current 200 mA or higher Displays EXT when power is supplied from the USB connector Charging Nickel Metal Hydride Batteries You can charge nickel metal hydride batteries inserted in the unit When charging nickel metal hydr...

Страница 8: ...e unit and then insert the other end into the hole on the other side Insert a pointed object such as a ball point pen between the belt clip and the unit and pry the end of the belt clip from the hole on the side of the unit Note Note Push the bottom of the belt clip to make some space between the belt clip and the unit 1 align the belt clip with the two vertical grooves on the shoe mount adapter a...

Страница 9: ...splayed setting that is flashing is saved The same applies when setting other parameters The frequency indicator changes in response to the channel number The unit continues to receive even when setting the receive channel If the power supply cuts off while you are configuring settings perform the configuration procedure again from the beginning Make sure that the same channel is set on transmitte...

Страница 10: ...g the compander mode may be necessary You can configure different compader modes for tuner 1 and tuner 2 When operating in conjunction with UWP D series transmitters set the transmitters to the same compander mode No audio will be output if the tone signal frequency is different due to inconsistencies in compander mode settings configured on the devices being used together 1 Press the MENU button ...

Страница 11: ...nt to change to that frequency 6 Use the or button to select YES then press the SET button on the transmitter This sets the transmit channel and compander mode The infrared transmission from the unit in step 3 continues for about 10 seconds Perform steps 4 and 5 within those 10 seconds If 10 seconds have elapsed you can reestablish the infrared link using the SYNC screen on the unit Place the unit...

Страница 12: ...is turned off Menu Displays and Detailed Settings Menu Structure and Hierarchy Menu structure UTILITY menu You can display the UTILITY menu from the meter screen which displays information on tuners 1 and 2 This menu allows you to configure basic settings for the unit RX1 tuner 1 menu This menu allows you to configure settings for RX1 tuner 1 RX2 tuner 2 menu This menu allows you to configure sett...

Страница 13: ...justing the Monitor Audio Level page 12 Displaying the accumulated running time TIME Display the accumulated running time of the unit as a guide to total usage time The factory default setting is 00 00 Up to 99 99 can be displayed To reset the time display 1 Press and hold the SET button until the time display starts flashing 2 Press the button to display 00 00 CLR and press the SET button Pressin...

Страница 14: ...nel automatically AUTO SET Automatically search for and set an available channel and start infrared transmission to the transmitter For details see Searching for available channels and configuring the channel settings via infrared communication AUTO SET page 11 Selecting the frequency band BAND Select the receive frequency band This menu is not available on Japanese and Korean models On these mode...

Страница 15: ...onnector for audio inputs ASSIGN Select the connector from which to output signal inputs OUT1 Output the audio from the OUTPUT 1 connector If the connected microphone is an LR type the output will be mixed OUT1 2 L R Output the audio from both the OUTPUT 1 and OUTPUT 2 connectors If the connected microphone is an LR type L will be output from the OUTPUT 1 connector and R will be output from the OU...

Страница 16: ...e transmitters are not set to the channels within the same channel group The channel plan is set so that no signal interference occurs when two or more transmitters are used simultaneously Set each transmitter to a different channel within the same channel group Adjacent channels are being used Use the channels separated by at least two channels 250 kHz Jamming radio waves are being received Set t...

Страница 17: ...utput level 5 mW 16 Ω Audio input output connector 3 5 mm diameter mini jack Reception method Space diversity system true diversity system during one channel operation Local oscillator Crystal controlled PLL synthesizer Receive frequencies Models available in USA 470 MHz to 542 MHz UC14 model 566 MHz to 608 MHz and 614 MHz to 638 MHz UC30 model 638 MHz to 698 MHz UC42 model Models available in Eur...

Страница 18: ...MP conversion cable 1 Battery case 1 Chinese model only Before Use 1 CD ROM 1 Warranty card 1 North American and Korean models only Design and specifications are subject to change without notice 63 2 1 2 28 4 1 1 8 82 3 1 4 Units mm inches Notes Always verify that the unit is operating properly before use SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO COMPENSATION OR ...

Страница 19: ...Sony Corporation ...

Отзывы: