background image

Transmitter Settings

29

Setting the display contrast (CONTRAST)

You can adjust the contrast of text and icons on the 
display in the range 1 to 10.
The configurable values are given below.
(Light) 

1 2 3 4 5 6 7 8 9 10

 (Dark)

This function is displayed in extended mode only.

Restoring factory default settings 
(RESET)

Restores all parameters to their factory default settings.
Press and hold the SET button. A prompt appears asking 
you whether to restore factory default settings. Press the 
+ or – button to select YES, then press the SET button. 
The transmitter parameters are restored to their factory 
default settings.

• This function can be used in transmission stopped mode 

only.

• After a reset, the audio input level is also restored to its 

factory default setting. Note that this may cause the 
volume on devices connected to the tuner and in 
headphones to suddenly change.

Displaying the software version 
(VERSION)

Displays the software version of the transmitter. 

This function is displayed in extended mode only.

Note

Notes

Note

Содержание URX-P03

Страница 1: ...hone Package Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference UWP D11 D12 D16 UTX B03 UTX M03 UTX P03 URX P03 4 530 735 18 1 2014 Sony Corporation ...

Страница 2: ...e hand held microphone UTX M03 17 Attaching accessories to the plug on transmitter UTX P03 17 Attaching accessories to the portable diversity tuner URX P03 18 Operation 19 If noise is generated 19 Tuner Settings 20 Menu structure and operation 20 Setting the receive channel 21 Searching for available channels within a group Clear Channel Scan 21 Searching for active channels within a group Active ...

Страница 3: ...e consists of a body pack transmitter UTX B03 a portable diversity tuner URX P03 and their accessories When used in conjunction with a compact camcorder a mobile system for ENG Electronic News Gathering or EFP Electronic Field Production applications can be constructed Note Body pack transmitter UTX B03 1 Portable diversity tuner URX P03 1 Supplied accessories Wind screen 1 Omni directional lavali...

Страница 4: ...ews Gathering or EFP Electronic Field Production applications can be constructed Microphone holder 1 XLR BMP conversion output cable for the URX P03 1 Shoe mount adapter 1 Belt clip 1 Battery case 1 Chinese model only Before Use 1 Quick Start Guide 1 CD ROM 1 Warranty card 1 North American and Korean models only Stereo mini plug BMP conversion cable 1 Supplied accessories Hand held microphone UTX ...

Страница 5: ...c Field Production applications can be constructed Body pack transmitter UTX B03 1 Portable diversity tuner URX P03 1 Supplied accessories Soft case 1 Plug on transmitter UTX P03 1 Shoe mount adapter 1 Belt clip 2 Wind screen 1 Holder clip 1 Stereo mini plug BMP conversion cable 1 XLR BMP conversion output cable for the URX P03 1 Omni directional lavalier microphone 1 Battery case 1 Chinese model ...

Страница 6: ...rican and Korean models only UTX M03 Hand held microphone UTX M03 1 Microphone holder 1 Before Use 1 CD ROM 1 Warranty card 1 North American and Korean models only UTX P03 Plug on transmitter UTX P03 1 Soft case 1 Battery case 1 Chinese model only Before Use 1 CD ROM 1 Warranty card 1 North American and Korean models only URX P03 Portable diversity tuner URX P03 1 Shoe mount adapter 1 Belt clip 1 ...

Страница 7: ...also features a Clear Channel Scan function to search for available channels automatically UWP D12 Hand held microphone UTX M03 This microphone features a robust metallic body It has a muting function and attenuator adjustment function to support a wide audio input level range It can be used in diverse applications simply by changing the microphone capsule It has a built in antenna Microphone unit...

Страница 8: ...available USB portable power supply When a USB portable power supply is connected while the power is turned on the unit automatically operates with power supplied by the USB portable power supply When a USB portable power supply is connected while nickel metal hydride batteries are inserted and the power is turned off the batteries are charged by the USB portable power supply Alkaline batteries an...

Страница 9: ...lays various functions Press the or button to switch functions For details see Configuration menu page 23 jSET button Adjusts displayed function settings and enters the displayed value Holding down the SET button while turning on the power turns the transmitter on without transmitting a signal transmission stopped mode kInfrared detector Receives the frequency and compander mode set on the tuner H...

Страница 10: ...age 23 gInfrared detector Receives the frequency and compander mode set on the tuner hSET button Adjusts displayed function settings and enters the displayed value Holding down the SET button while turning on the power turns the transmitter on without transmitting a signal transmission stopped mode iUSB connector Micro B type Connect to a commercially available USB portable power supply When a USB...

Страница 11: ...ransmission power indicator Indicates the current transmission power setting You can change the setting with the RF transmission power setting function For details on the RF transmission power setting function see Setting the transmit output level RF POWER page 27 C Audio input level meter Displays the audio input level D Peak indicator Lights up when the signal is 3 dB below the level at which di...

Страница 12: ... while the power is turned on the unit automatically operates with power supplied by the USB portable power supply When a USB portable power supply is connected while nickel metal hydride batteries are inserted and the power is turned off the batteries are charged by the USB portable power supply Alkaline batteries and lithium batteries cannot be recharged kBattery compartment Accepts two AA batte...

Страница 13: ...r on without sending a signal transmission stopped mode jPOWER button Turns the power on off kOUTPUT audio output connector 3 5 mm diameter stereo mini jack Connect one end of the supplied XLR BMP conversion output cable for the URX P03 or the stereo mini plug BMP conversion cable here and the other end to the microphone input on a camcorder mixer or amplifier If the microphone input connector on ...

Страница 14: ...ailable can be specified using the PWR SOURCE external power selection function Under the factory default setting the power supplied from inserted AA batteries has precedence For details about inserting batteries and displaying the battery level or supplying power from supply connected to the USB connector see the following sections For details on the PWR SOURCE function setting see Selecting the ...

Страница 15: ...BATTERY function setting see Setting the battery type BATTERY page 24 Battery precautions Batteries may leak or explode if mistreated Be sure to follow these instructions Insert batteries in the correct 3 and polarity orientation Always replace the two batteries together with new ones Do not use different types of batteries or old and new ones together Dry cells are not rechargeable When not using...

Страница 16: ...arging may not be supported depending on the connected AC adapter portable power supply or computer port Nickel metal hydride batteries are not charged while the transmitter or tuner is turned on Attaching Accessories This section describes how to attach the supplied accessories to each device Attaching accessories to the body pack transmitter UTX B03 Connecting the microphone Be sure to attach or...

Страница 17: ...X P03 Attaching a microphone or cable Align and insert the microphone into the hole in the wind screen Insert one end of the belt clip into one of two holes on either side of the transmitter and then insert the other end into the hole on the other side Insert a pointed object such as a ball point pen between the belt clip and the transmitter and pry the end of the belt clip from the hole on the si...

Страница 18: ...ton and pull the microphone or cable out slowly Release button Microphone or cable connector Example XLR BMP conversion output cable for the URX P03 For a secure connection turn to lock the connector Note Note Push the bottom of the belt clip to make some space between the belt clip and the tuner 1 align the belt clip with the two vertical grooves on the shoe mount adapter and insert the adapter i...

Страница 19: ...T button on the transmitter This sets the transmit channel The infrared transmission from the tuner in step 5 continues for about ten seconds Perform steps 6 and 7 within those ten seconds If ten seconds have elapsed you can reestablish the infrared link using the SYNC menu on the tuner Place the tuner and transmitter within about 20 cm 8 in of each other If five seconds elapse without any user in...

Страница 20: ...n OUT LEVEL audio output level setting SYNC infrared transmitter function TIME accumulated running time display MENU MODE menu display mode setting Extended mode This mode displays all configuration menus You can enable extended mode by setting MENU MODE menu display mode to ADVANCED The existing settings configured in extended mode are active even when using simple mode Configuration menus GP CH ...

Страница 21: ...el number then press the SET button The displays stops flashing and the desired channel is set If there is no user input within ten seconds after the channel group display or channel number display starts flashing the displayed setting that is flashing is saved The same applies when setting other parameters The frequency indicator changes in response to the channel number The tuner continues to re...

Страница 22: ...fied channel group This is useful when using more than one tuner in combination with a single transmitter Before performing this procedure select the channel group For details see Setting the receive channel page 21 1 Use the or button to display the ACT SCAN menu 2 Press and hold the SET button for one second or longer Press and hold until the channel group and display starts flashing 3 Press the...

Страница 23: ...itor output level is adjusted separately For details about adjusting the monitor audio level see Adjusting the monitor audio level page 22 Using infrared transmission SYNC Transfers the frequency and compander mode set on the tuner to a transmitter using an infrared transmitter 1 Use the or button to display the SYNC menu 2 Press and hold the SET button for one second or longer A confirmation scre...

Страница 24: ...er supply will be used regardless of the PWR SOURCE setting There may be a brief interruption in the audio when the power supply switches Setting the frequency to an active channel ACT SCAN Searches for channels already in use This is useful when using more than one tuner in combination with a single transmitter This function is displayed in extended mode only For details see Searching for active ...

Страница 25: ...ters UTX B03 M03 P03 There are three menu display modes that can be selected according to the application Simple mode This mode displays only the required settings for transmitting audio You can enable simple mode by setting MENU MODE menu display mode to SIMPLE Configuration menus GP CH group channel select BAND frequency band select Not available on Japanese and Korean models RF POWER RF transmi...

Страница 26: ...the power on and to display the transmission stopped mode menu The following configuration menus can only be modified in transmission stopped mode GP CH group channel select BAND frequency band select Not available on Japanese and Korean models RF POWER RF transmit output level select RESET factory default setting function Basic menu operation The basic menu operation is the same in simple mode ex...

Страница 27: ...model This function can be modified in transmission stopped mode only Adjusting the audio input attenuation level ATT You can set the audio input attenuation level in 3 dB increments to reduce noise distortion The factory default setting is 9 dB UTX B03 or 0 dB UTX M03 and UTX P03 On the UTX B03 P03 is displayed if IN LEVEL is set to LINE and the attenuation level cannot be modified fixed at 0 dB ...

Страница 28: ...mode only The POWER MUTING button lock state does not change after switching to simple mode after setting the button to LOCK in extended mode If the batteries are removed and reinserted while the POWER MUTING button is set to LOCK the power will turn on automatically but the lock state of the POWER MUTING button does not change Muting the output MUTING Pressing the POWER MUTING button while transm...

Страница 29: ...t appears asking you whether to restore factory default settings Press the or button to select YES then press the SET button The transmitter parameters are restored to their factory default settings This function can be used in transmission stopped mode only After a reset the audio input level is also restored to its factory default setting Note that this may cause the volume on devices connected ...

Страница 30: ...eries devices Sample configuration for ENG Electronic News Gathering or EFP Electronic Field Production with a camcorder Portable diversity tuner URX P03 with shoe mount adapter attached Body pack transmitter UTX B03 XDCAM EX HDV camcorder HXR NX3 etc or 1 XLR BMP conversion output cable supplied Hand held microphone UTX M03 ...

Страница 31: ...circuit Restart the unit If the message persists contact your point of purchase or Sony service representative NO TONE Audio signal output has been muted because a tone signal different from the compander mode configured on the tuner was received Configure the appropriate compander mode based on the transmitters you are using Setting the compander mode COMPANDER page 24 When operating in conjuncti...

Страница 32: ...ter is different from that on the tuner Use the same channel setting on both the transmitter and tuner The transmitter is not transmitting signals or the transmission output is weak Confirm that the transmitter is turned on Alternatively reduce the distance between the transmitter and tuner The transmitter is set to line level input 2 Switch to microphone input The compander mode setting on the tr...

Страница 33: ...ls are being used Use the channels separated by at least two channels 250 kHz The RF indicator on the tuner lights up even when the transmitter is off Jamming radio waves are being received Set the channel on the tuner to a channel for which the RF indicator does not light or use the Clear Channel Scan function to switch to a channel without interference Then set the transmitter to the same channe...

Страница 34: ... 000 MHz to 956 125 MHz and 956 625 MHz to 959 625 MHz U90 model Models available in Europe 470 MHz to 542 MHz CE21 model 566 MHz to 630 MHz CE33 model 638 MHz to 694 MHz CE42 model Model available in China 710 MHz to 782 MHz CN38 model Model available in Korea 925 MHz to 937 5 MHz KR Model Model available in Thailand and Taiwan 794 MHz to 806 MHz E model Preemphasis 50 μs Reference deviation 5 kH...

Страница 35: ...rea Dimensions 63 82 20 mm 2 1 2 3 1 4 13 16 in Width height depth excluding antenna Mass Approx 103 g 3 6 oz excluding batteries Lavalier microphone ECM V1BMP Type Electret condenser microphone Frequency response 40 Hz to 20 000 Hz Directivity Omni directional Sensitivity 43 0 3 dB 0 dB 1 V Pa at 1 kHz Operating temperature 0 C to 50 C 32 F to 122 F Storage temperature 20 C to 55 C 4 F to 131 F C...

Страница 36: ... Thailand Taiwan and Korea During 48V ON and ECM 673 connection Approx 6 hours with output power of 40 mW for model available in USA Approx 6 hours with output power of 30 mW for model available in Europe and China Approx 7 hours with output power of 10 mW for model available in Thailand Taiwan and Korea Dimensions 41 5 102 41 5 mm 1 11 16 4 1 8 1 11 16 in width height depth including the audio in...

Страница 37: ...one signal In UWP D compander mode 32 382 kHz In UWP compander mode 32 kHz In WL800 compander mode 32 768 kHz Indicators POWER RF Operating temperature 0 C to 50 C 32 F to 122 F 0 C to 35 C 32 F to 95 F when charging Storage temperature 20 C to 55 C 4 F to 131 F Supply voltage 3 0 V DC two LR6 AA size alkaline batteries 5 0 V DC supplied from USB connector Battery life Approx 6 hours measured with...

Страница 38: ...Sony Corporation ...

Отзывы: