21
KV-21FK120
KV-21FK120
3-1.
X
R565 CONFIRMATION METHOD
(HV HOLD-DOWN CONFIRMATION) AND
READJUSTMENTS
The following adjustments should always be performed when replacing
the following components which are marked with
Y
on the schematic
diagram:
DY, T585, CRT, IC001, IC561,
IC600, C506, C507, C508, T511,
L510, C588, L588, C566, C561,
C563, D567, D568, D566, PH602,
R567, R568, R565, R566, R562,
R563, R561, R528……....A Board
HV HOLD-DOWN
R565
Part Replaced (
Y
)
Adjustment (
X
)
Preparation Before Confi rmation
1. Using a Variac, apply AC input voltage: 120 ± 2 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and BRIGHTNESS
controls to maximum.
4. Confi rm that the voltage between C566 (+) or TP30 and ground is
more than 97 VDC.
Hold-Down Operation Confi rmation
1. Connect the current meter between Pin 11 of the FBT (T585) and the
PWB land where Pin 11 would normally attach (See Figure 1 on the
next page).
2. Input a dot signal and set PICTURE and BRIGHTNESS to minimum:
IABL = 100 ± 100µA.
3. Confi rm the voltage of A Board TP-23 is 135.6 ± 1VDC.
4. Connect the digital voltmeter and the DC power supply via Diode
1SS119 to C566 (+) and ground (See Figure 1 on next page).
5. Increase the DC power voltage gradually until the picture blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication standard < 117.0 VDC.
8. Input a white signal and set PICTURE and BRIGHTNESS to
maximum: IABL = 1350 ± 100µA.
9. Repeat steps 4 through 7.
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation
cannot be met, readjustment should be performed by altering the
resistance value of R565 component marked with
X
.
+
IABL
ABL
T585
FBT
range
-
Ammeter
3.0 mA DC
A
3-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Note: The following adjustments should always be performed when
replacing the following components, which are marked with
Y
on the
schematic diagram on the A Board:
A BOARD:
Y
IC600, PH602
1. Using a Variac, apply AC input voltage: 130 + 2.0 / - 0.0 VAC.
2. Input a DOT pattern at Q.C.
3. Set the PICTURE and the BRIGHTNESS controls to minimum.
4. Confi rm the voltage of A Board between TP-23 & Ground is =135.6 ±
1VDC.
5. If step 4 is not satisfi ed, replace the components listed above, then
repeat steps 1 through 3.
SECTION 3: SAFETY RELATED ADJUSTMENTS
Содержание TRINITRON RM-Y194
Страница 65: ...User Guide ...
Страница 71: ...User Guide ...
Страница 77: ......
Страница 91: ......
Страница 107: ......
Страница 108: ...Connecting Additional Equipment 37 Anotaciones ...
Страница 109: ...User Guide 38 Anotaciones ...
Страница 110: ...Connecting Additional Equipment 39 Anotaciones ...
Страница 111: ...Sony Corporation http www sony net Printed in U S A ...