– 46 –
KV-XA25M80/XA25M83/XA25N90
RM-954
RM-914
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far.
(Less than 8 mm)
(2) Dynamic Convergence Adjustment
Preparation:
•
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to
[MIN] and [BRIGHTNESS] to [STANDARD] .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom
of the screen are straight.
Blue
Red
VM1 board
Blue
Red
VM1 board
Neck assy
Neck assy
R B
R B
TLH
TLV
YCH
XCV
B
R
R
B