– 15 –
KV-T25SN81
RM-870
3-2. CONVERGENCE
Preparation :
•
Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
•
Minimize the brightness setting.
•
Provide dot pattern.
(1)
Horizontal and Vertical Static Convergence
1. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots in the center of the screen are separated
from each other.
2. Adjust the BMC (Hexapole) magnet so that the red, green and
blue dots are aligned in a straight line.
3. Adjust the BMC (Hexapole) magnet so that the red, green and
blue dots are balanced (ie. equal distance) on either side of the
green dot.
4. (Moving horizontally), adjust the H.STAT VR magnet so that
the red, green and blue dots converge on top of each other in
the center of the screen.
•
The respective dot positions resulting from moving each magnet
interact, so be sure to perform adjustment while tracking.
Use the V. STAT magnet to adjust the red, green and blue dots
so they coincide at the center of screen (by moving the dots in
the horizontal direction).
BMC (Hexapole)
V.STAT
Purity
•
Operation of the V.STAT magnet.
If the V-STAT magnet is moved in the direction of the
a
and
b
arrows, the red, green and blue dots move as shown below.
B
R
B
R
a
b
b
b
a
b
a
b
a
R
G
B
b
B
G
R
b
b
a
a
1
2
3
G
G
B G R
R G B
•
Operation of BMC (Hexapole) Magnet.
To align or balance the red, green and blue dots, adjust the BMC
(Hexapole) magnet as shown below.
R G
B
R
G
B
R
G B
R
G
B
R
G
B
R
G
B
R G B
G
R
B
Center dot
V.STAT Magnet
C board
RV 701
SCREEN (G2)