– 27 –
KV-LX34M50
RM-871
5-2. ADJUSTMENT METHOD
Item Number 00
This explanation uses V-Position as an example.
1. Select 00 VSH with the
1
and
4
buttons.
2. Raise/lower the data with the
3
and
6
buttons.
3. Select the optimum state. (The standard is 1F for PAL reception.)
4. Write with the
[MUTING]
button. (The display changes to
WRITE.)
5. Execute the writing with the
-
button. (The WRITE
display will be changed back to SERVICE.)
Use the same method for Items Number 00-99. Use
1
and
4
to
select the adjustment item, use
3
and
6
to adjust, write with
[MUTING]
, then execute the write with
-
.
Note : 1. For adjustment items that have different standard data
between 50Hz or 60Hz and normal or wide, be sure to
use the respective input signal while adjusting.
2. In
[WRITE]
, the data for all items are written into memory
together.
1F
VSH
00
1F
VSH
Data adjusted with
[3]
and
[6]
buttons.
Written with
[MUTING]
Write executed with
[0]
The WRITE display
then changes back to
SERVICE.
1F
VSH
00
SERVICE 50
WRITE 50
WRITE 50
00
Item selected with
[1]
and
[4]
buttons.
The display change from