![Sony TRINITRON KV-J25MF8J Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/sony/trinitron-kv-j25mf8j/trinitron-kv-j25mf8j_service-manual_1330291012.webp)
– 12 –
When measuring the power supply voltage,
just remove a part of bracket shown below.
1
PCB holder
2
Chassis assy
2
Two screws
(+BVTP3 x 8)
(7-685-646-71)
Cut the four marked sections
with a nippers to remove a
part of bracket.
1
For safety reason this plate
must be remounted after
cutting and taking away.
2
ATTENTION
SAFETY REQUIREMENT
1
2-6. A AND D BOARDS REMOVAL
7
D board
1
Four
connectors
4
A Board
3
Three
claws
6
Four claws
2
Five screws
(+BVTP3 x12)
5
Two screws
(+BVTP3 x12)
2-5. S1 BOARD REMOVAL
2-4. SERVICE POSITION
4
S1 Board
2
One claw
3
PCB holder
1
Screw
(+BVTP3x12)