– 55 –
KV-HR29M91/HR34M91
RM-1007
RM-1007
4-12. WHITE BALANCE ADJUSTMENT
(1).VIDEO MODE : AV PRO
PICTURE : Maximum
COLOR
: Minimum
Color Temp.: High
DRC-MF
: Progressive
(2). Receive the all white signal and set to full mode screen and
to the service mode.
(3). Minimize the cut-offs and make drives normal in the follow-
ing items.
Category
Reg. No & Name
COLR
3 GDRV
4 BDRV
6 GCUT
7 BCUT
(4). Adjust with the cut-offs and the drives mutually the white
balance becomes best in the mode the picture is maximum or
minimum.
4-13. FOCUS ADJUSTMENT 2
Note
Focus adjustment should be completed before W/B adjustment.
(1) Receive digital monoscope pattern.
(2) Set DRC-MF to “Progressive” and PICTURE to “Standard”.
(3) Adjust FOCUS VR so that the center of the screen becomes
justfocus.
(4) Change the receiving signal to white pattern and blue back.
(5) Confirm MAGENTA RING should not be over the limit sam-
ple. In case MAGENTA RING is over the limit sample,
adjust FOCUS VR to take tracking of MAGENTA RING and
FOCUS.
FOCUS
SCREEN G2
FLYB ACK TRANSFORMER (T8001)
Содержание TRINITRON KV-HR29M91
Страница 105: ...KV HR29M91 HR34M91 RM 1007 RM 1007 148 147 Conductor side SF LANDING Comporent side ...
Страница 106: ...KV HR29M91 HR34M91 RM 1007 RM 1007 Conductor side Comporent side LAMDIMG SFH 149 150 ...
Страница 107: ...KV HR29M91 HR34M91 RM 1007 RM 1007 151 152 T TELE TEXT Conductor side Component side ...
Страница 109: ...KV HR29M91 HR34M91 RM 1007 RM 1007 155 156 Conductor side 2 3 4 5 6 7 8 A 1 B C D E F G ...
Страница 110: ... 157 KV HR29M91 HR34M91 RM 1007 RM 1007 W VM ...
Страница 157: ... 204 KV HR29M91 HR34M91 RM 1007 RM 1007 9 965 395 01 Sony EMCS Corporation Ichinomiya TEC English 2003LR02 1 2003 12 ...