– 19 –
KV-G21PD1
RM-883
5-2. ADJUSTMENT METHOD
Item Number 08
This explanation uses V-SHIFT as an example.
1. Select 08 V-SHIFT with the
[1]
and
[4]
buttons.
2. Raise/lower the data with the
[3]
and
[6]
buttons.
3. Select the optimum state. (The standard is 0F for PAL
reception.)
4. Write with the
[MUTING]
button. (The SERVICE display will
change to WRITE)
5. Execute the writing with the
[0]
button. (The WRITE
display will be changed back to SERVICE.)
Use the same method for Items Number 00-33. Use
[1]
and
[4]
to
select the adjustment item, use
[3]
and
[6]
to adjust, write with
[MUTING]
, then execute the write with
[0]
.
Write executed with
[0]
.
Written with
the
[MUTING]
.
WRITE
WRITE
GREEN
0C
VSF
08
SERVICE
50
50
50
GREEN
0C
VSF
08
GREEN
The WRITE display
will be changed back
to SERVICE.
0C
VSF
08
Adjust with the
[3]
and
[6]
buttons.