— 8 —
KV-38DRC2 / 38DRC2C
SELF DIAGNOSIS
2: +B OCP
N/A
3: +B OVP
N/A
4: V STOP
0
5: AKB
1
6: LOWB
0
7: H-STOP
0
101: WDT
24
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you
have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
Channel 8
ENTER
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
+B Overcurrent (OCP)
Occurs when an overcurrent
(more than 6A) on the +B
(135V) line is detected by
R6598/R6591. It will cause
Q6520 to turn on and force the
AC relay to turn off through
Q6532 and Q6530.
+B Overvoltage (OVP)
Occurs when 1) overvoltage
(more than +140V) on the
+B (135V) line is detected by
IC6505, or 2) an overvoltage
(more than 7.5 V) on the unreg
7V line is detected by D6014.
The AC relay will turn off
through Q6532 and Q6530.
Vertical Defl ection Stopped
Occurs when an absence of
the vertical defl ection pulse
is detected by IC201. Power
supply will shut down when
waveform interval exceeds 2
seconds.
White Balance Failure
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC201. TV will stay on, but there
will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).
Low B OCP/OVP Error
Occurs when set 5V is out.
Horizontal Defl ection Stopped
Occurs when either: 1) a +B overcurrent is detected (IC5007), or 2) overheating is detected (Thermistor TH5002).
Numeral “0” means that no fault
was detected.
Numeral “1” means a fault was detected
one time only.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially,
in rapid succession, as shown below:
DISPLAY
Channel 5
Sound volume -
Power ON.
AKB
VPROT
HPROT
SCL
SDA
IC701
MAIN UCOM
STBY LED
HA
STR
STBY-LED
OCP
OVP
LOW B ERR
AC RLY
CLKO
DATO
29
30
69
43
45
44
48
Q6532
Q6530
D6537
D6501
Q6527
RY6501
SET ON
200V OCP
+B OCP
OVP
D8027
D8003
0
0
I
UNREG 7V
D6014
D6018
SET 5V
26
25
58
35
34
CRT
VDY -
R5125
R5104
R5105
IC5007
2
14
Q5018
I5V
2
1
3
OVP
Q6522
STBY 5V
Q6524
Q6521
IC6505
+B OVP
+B
Q6520
IC6007
IC201
Y/C JUNGLE
D
A
A
A
D
Содержание Trinitron KV-38DRC2
Страница 158: ...408250641X book Page ii Wednesday May 30 2001 2 02 PM ...
Страница 162: ...408250641X book Page vi Wednesday May 30 2001 2 02 PM ...
Страница 164: ...408250641X book Page vi Wednesday May 30 2001 2 02 PM ...
Страница 210: ...408250641X book Page 46 Wednesday May 30 2001 2 02 PM ...
Страница 224: ...408250641X book Page 60 Wednesday May 30 2001 2 02 PM ...
Страница 225: ...408250641X book Page 61 Wednesday May 30 2001 2 02 PM ...
Страница 226: ...408250641X book Page 62 Wednesday May 30 2001 2 02 PM ...
Страница 227: ...408250641X book Page 63 Wednesday May 30 2001 2 02 PM ...
Страница 228: ...408250641X book Page 64 Wednesday May 30 2001 2 02 PM ...
Страница 229: ...408250641X book Page 65 Wednesday May 30 2001 2 02 PM ...
Страница 230: ...408250641X book Page 66 Wednesday May 30 2001 2 02 PM ...
Страница 231: ...408250641X book Page 67 Wednesday May 30 2001 2 02 PM ...
Страница 232: ...Printed in U S A 408250641X book Page 68 Wednesday May 30 2001 2 02 PM ...