KV-34DRC430/36DRC430
17
KV-34DRC430/36DRC430
ECG WIRE DRESSING (KV-36DRC430 ONLY)
DY
Rotation
COIL
CRT BRKT
NOTE: Leads are
dressed inside
Rotation Coil.
NOTE2: There are
2 Leads (TOTAL 4
Wires) to connect
to CH-Board
ECG - P/N
1-900-808-30 - 30 WCRT
1-900-808-31 - 34W CRT
SPRING (2 places)
Integral part of
the Ground wire
2-022-978-01
Wire Clip (2 Places)
DY
Rotation
COIL
CRT BRKT
Earth Coating
Ground Wire (ECG)
32”: 1-900-808-29
36”: 1-900-808-28
(Earth Coating Ground)
Integral Spring
2-Places
NOTE: Leads are
dressed inside
Rotation Coil.
NOTE2: There are
2 Leads (TOTAL 4
Wires) to connect
to CH-Board
Caution Points:
1. Make sure braided ECG wire loop does not
twist, and stays flat on CRT surface.
2. Do not pull excessively on the tension spring.
3. If the spring appears warped or stretched,
replace entire parts. The braided ECG wire
CANNOT sag on the CRT, and must remain
under tension.
ECG WIRE DRESSING (KV-34DRC430 ONLY)