7
KV-29FS105/34FS105/38FS105
KV-29FS105/34FS105/38FS105
SELF-DIAGNOSTIC FUNCTION
Display of Standby/Timer LED Flash Count
3 times
2 times
4 times
5 times
9 times
10 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
Diagnostic Item
Flash Count*
+B Overcurrent
2 times
+B Overvoltage
3 times
V-STOP
4
times
IK
(AKB)
5
times
Zero Cross
9 times
9V
10
times
*One fl ash count is not used for self-diagnostic.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
Self Diagnosis
Supported model
Standby/Timer LED
Diagnostic Item
No. of times
STANDBY / TIMER
lamp flashes
Probable Cause Location
Detected Symptoms
Power does not turn on
Does not light
•
Power cord is not plugged in.
•
Fuse is burned out (F601). (GK Board)
•
Power does not come on.
•
No power is supplied to the TV.
•
AC Power supply is faulty.
+B overcurrent (OCP)*
2 times
•
H.OUT (Q502) is shorted. (A Board)
•
IC702 is shorted. (C Board)
•
Power does not come on.
•
Load on power line shorted.
+B overvoltage (OVP)
3 times
•
IC501 is faulty. (A Board)
•
If a high is supplied to pin 2 of IC501.
(A Board)
•
Has entered standby mode.
I-Prot
4 times
•
+12V is not supplied. (A Board)
•
IC561 is faulty. (A Board)
•
Has entered standby state after
horizontal raster.
•
Vertical deflection pulse is stopped.
•
Power line is shorted or power
supply is stopped.
IK (AKB)
5 times
•
Video OUT (IC561) is faulty. (A Board)
•
IC702 is faulty. (C Board)
•
Screen (G2) is improperly adjusted. **
•
No raster is generated.
•
CRT Cathode current detection
reference pulse output is small.
Zero Cross
9 times
•
No zero cross pulses on pin 45
IC1001. (A Board)
•
Power does not come on.
9V Check
10 times
•
Relay failed (RY600)
•
Power does not come on.
* If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first
by the microcontroller is displayed on the screen.
** Refer to Screen (G2) adjustments in Section 2-4 of this manual