— 26 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
4-6-6. SUB HUE, SUB COLOR ADJUSTMENT
(SHUE, SCOL)
1. Input color-bar signal at 75%.
2. Activate the Service Adjustment Mode.
3. Set (PIC) to Max and (COL) to 50%.
4. Connect an oscilloscope probe to C Board, CN705Pin 4 Blue Out.
5. Select the SHUE and SCOL item with 1 and 4 .
6. While showing the SHUE item, adjust the waveform with 1 and 4
until the second and third bars show the same level
(V2 = V3 < 0.15Vp-p).
7. While showing the SCOL item, adjust the waveform with 3 and 6
until the first and fourth bars show the same level
(V1 = V4 < 0.15Vp-p). Increase 1 step after adjustment for 34FV250
and 38FV250 models.
NOTE
: SCOL must be adjusted in all modes NTSC, PAL-M, and PAL-N.
V1 V2 V3 V4
8. Press MUTING then ENTER to save into the memory.
4-6-7. V. SIZE ADJUSTMENT (VSIZ)
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the VSIZ item with 1 and 4 .
4. Adjust value of VPOS with 1 and 4 for the best vertical center.
5. Press MUTING then ENTER to save into the memory.
4-6-8. V. CENTER ADJUSTMENT (VPOS)
Perform this adjustment after performing H. Frequency
(Free Run) Check.
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the VPOS item with 1 and 4 .
4. Adjust value of VPOS with 3 and 6 for the best vertical center.
5. Press MUTING then ENTER to save into the memory.
4-6-9. H. CENTER ADJUSTMENT (HPOS)
Perform this adjustment after performing H. Frequency
(Free Run) Check.
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select the HPOS item with 1 and 4 .
4. Adjust the value of HPOS with 3 and 6 for the best horizontal center.
5. Press MUTING then ENTER to save into the memory.
4-6-10. H. SIZE ADJUSTMENT (HSIZ)
1. Input a monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select HSIZ with 1 and 4 .
4. Adjust with 3 and 6 for the best horizontal size.
5. Press MUTING then ENTER to save into the memory.
4-6-11. V. LINEARITY (VLIN), V. CORRECTION
(SCOR), PIN AMP (PAMP), AND
HORIZONTAL TRAPEZOID (HTRP)
ADJUSTMENTS
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select VLIN, SCOR, PAMP, and HTRP with with 1 and 4.
4. Adjust with 3 and 6 for the best horizontal size.
5. Press MUTING then ENTER to save into the memory.
V LINEARITY (VLIN)
V CORRECTION (SCOR)
PIN AMP (PAMP)
HORIZONTAL TRAPEZOID (HTRP)
Содержание TRINITRON KV-29FS100
Страница 32: ... 32 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Страница 33: ... 33 KV 29FS100 29FV300 34FS100 34FV250 38FV250 A BOARD WAVEFORMS ...
Страница 34: ... 34 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Страница 35: ... 35 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Страница 36: ... 36 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Страница 37: ... 37 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...