— 17 —
KV-27V42/27V66/29SL42K/29SL42T/29VL42T/29XL42T
4-1.
R584 CONFIRMATION METHOD
(HV HOLD-DOWN CONFIRMATION)
AND READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with
on the schematic diagram.
DY, C511, C573, C574, C575, D572, D573, D574,
R582, R583, R585, R586, R578, R625, R626, T504, IC301,
IC521, IC602, C507, C508, C505, C509, C515, C520, L591,
L501
Preparation Before Confirmation
1. Using a Variac, apply AC input voltage: 120 ± 2 VAC
(or 120-220 ± 2 VAC for KV-29SL42K).
2. Turn the POWER switch ON.
3. Input an entirely white signal and set the PICTURE and
BRIGHTNESS controls to maximum.
4. Confirm that the voltage between C574 (+) or TP503
and ground is more than 105 VDC.
Hold-down Operation Confirmation
1. Connect the current meter between Pin 11 of the FBT
(T504) and the PCB land where Pin 11 would normally
attach. (See Figure 1 on the following page.)
2. Input a dot signal and set PICTURE and BRIGHTNESS
to minimum: IABL = 100 + 100/-95
mA.
3. Confirm the voltage of A Board TP-600 is
135 ± 3 VDC.
4. Connect the digital voltmeter and the DC power supply
via diode 1SS119 to C574 (+) and ground.
(See Figure 1 on the following page.)
5. Increase the DC power voltage gradually until the picture
blanks out.
6. Read the digital voltmeter indication.
(standard: less than or equal to 141.3 VDC).
7. Turn DC power source off immediately
8. Input a white signal and set PICTURE and BRIGHTNESS
to maximum.
9. Repeat steps 4 to 7.
SECTION 4
SAFETY RELATED ADJUSTMENTS
Hold-down Readjustment
If the setting indicated in step 2 of Hold-down Operation
Confirmation cannot be met, readjustment should be performed
by altering the resistance value of R584, a component marked
with
.
+
I ABL
ABL
FBT
Range
-
Ammeter
3.0 mA DC
A
4-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Note: The following adjustments should always be performed
when replacing the following components, which are marked
with on the schematic diagram.
IC601, IC602
1. Using a Variac, apply AC input voltage: 130 ± 2 VAC
(or 120-220 ± 2 VAC for KV-29SL42K).
2. Input a dot signal.
3. Set the PICTURE and BRIGHTNESS controls to minimum.
4. Set to Service Adjustment Mode.
5. Select PADJ with
and
.
6. Adjust with
to the 0 level.
7. Confirm the voltage of A board TP-600 is less than
138 VDC.
8. If step 7 is not satisifed, replace the components and repeat
the above steps.
9. Supply 120 ± 2 VAC (or 120-220 ± 2 VAC for KV-
29SL42K) to the set with a variable auto transformer.
10. Adjust with
and
for 135 ± 3 VDC.
11. Press
then
to save into the memory.
T504