KV-21FT250
KV-21FT250
15
1) Dress AC Power Cord, Lead Assy, Earth and Lead Assy, Speaker (Right) inside standing purse lock.
Note : Do not lock the standing purse lock. (will be lock after putting in DGC Conn in Overall Assy)
Keep bunch of wires above of RY600 to avoid wires from being sandwiched with front jack and pushed against relay.
2) Dress AC Power Cord and Lead Assy, Speaker (Left) with Pin, Wire A016 as shown.
Note : Dress AC Power Cord & Lead Assy, Speaker (Left) above the surrounding capacitors to prevent from touching high-temp parts.
Lead Assy,
Lead Assy, Speaker
Figure 6(a)
AC Cord Holder
540 ± 5 mm
Heat Sink, A004
Dress AC Power Cord & Lead Assy,
Speaker (Left) above the surrounding
capacitors to prevent from touching high-
temp parte.
AC Power
RY600
Standing
Lead Assy, Speaker
Pin, Wire
2-7. AC POWER CORD AND SPEAKERS
y
y
p
(
g
)
g
Dress DGC Conn into standing purse lock and lock the standing purse lock.
Note : 1) AC Power Cord, Lead Assy, Earth and Lead Assy, Speaker (Right) already inserted into standing purse lock during Chassis Assy.
2) Keep bunch of wires above of RY600 to avoid wires from being sandwiched with front jack and pushed against relay.
3) Dress wires away from beznet's front terminal to prevent wires from being sandwiched when docking.
4) Dress speaker wires above the surrounding capacitors to prevent from touching high-temp parts.
Dress wires away from beznet's front terminal
--> prevent wires from being sandwiched when docking chassis.
Lead Assy, Speaker (Right)
AC Power Cord
Lead Assy, Earth
Keep bunch of wires above of RY600
--> to avoid wires from being sandwiched with
front jack and pushed against relay
DGC Conn
RY600
Standing Purse Lock
Pin, Wire A016
AC Power Cord
Lead Assy, Speaker
DGC
Lead Assy,
AC Power
Standing Purse
Lock
Lead Assy, Speaker (Left)
Wire dressing done during chassis
half way docked into beznet.
Dress speaker wires above the surrounding capacitors
--> prevent from touching high-temp parts.